New Mexico Administrative Code
Title 7 - HEALTH
Chapter 8 - RESIDENTIAL HEALTH FACILITIES
Part 3 - REGULATIONS GOVERNING RESIDENTIAL SHELTER CARE FACILITIES FOR CHILDREN
Section 7.8.3.126 - ACCESS REQUIREMENTS FOR THE DISABLED IN NEW FACILITIES FOR COMMUNITY HOMES

Universal Citation: 7 NM Admin Code 7.8.3.126

Current through Register Vol. 35, No. 18, September 24, 2024

A. Accessibility to the disabled must be provided in all new facilities and includes, at a minimum, the following:

B. Main entry into the facility must be level or incorporate a ramp to allow for wheelchair access.

C. Building layout must allow for access to main living area and dining area.

D. At least one (1) bedroom must have a door clearance of 32 inches.

E. At least one (1) toilet/bathing facility must provide a 60-inch diameter turning radius.

F. If ramps are used, the slope of each ramp must provide at least a 12-inch horizontal run for each inch of vertical rise.

G. Ramps exceeding a six-inch rise must be provided with handrails.

H. Additional access requirements may apply depending upon the size and complexity of the facility.

Disclaimer: These regulations may not be the most recent version. New Mexico may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.