A. All exit doors must have a minimum width of 36 inches.

B. All sleeping room doors must have at least one and three quarter inches bonded solid core, with a minimum width of 32 inches.

C. All doors to toilet and bathing facilities must have a minimum width of 24 inches.

D. Locks on doors to toilets must be of a type that the lock can be released from the outside.

E. Exit doors leading to the outside of a facility with a capacity of ten or more children must open outward.

F. Exit doors leading to the outside of a facility must be provided with a night latch, dead bolt or security chain, provided such devices open from the inside without the use of a key or tool and are mounted at a height not to exceed 48 inches above the finished floor.

G. Sleeping room doors for non-mobile children must be at least one and three quarter inches bonded solid core, with a minimum width of 44 inches.

H. Each sleeping room housing non-mobile children must have a 44-inch exit door leading directly to the outside.

Disclaimer: These regulations may not be the most recent version. New Mexico may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.