New Mexico Administrative Code
Title 14 - HOUSING AND CONSTRUCTION
Chapter 8 - PLUMBING CODES
Part 2 - 2021 NEW MEXICO PLUMBING CODE
Section 14.8.2.13 - CHAPTER 5 WATER HEATERS
Current through Register Vol. 35, No. 18, September 24, 2024
See this chapter of the UPC except as provided below.
A. 501.0 General. 501.1 Applicability. See this section of the UPC except delete the following sentence: "The minimum capacity for water heaters shall be in accordance with the first hour rating listed in Table 501.1(2)."
B. 507.13 Installation in residential garages. At the end of the last sentence delete the following text: "unless listed as flammable vapor ignition resistant".
C. 508.3 Appliances on roofs. 508.3.1 Access. See this section of the UPC except after the words "in height" add the following: "except those designated as R-3 occupancies."
D. 510.2.20 Chimneys and vents. See this chapter of the UPC except delete the following language: "Where vents extend outdoors above the roof more than 5 feet (1524mm) higher than required by Table 509.6.1, and where vents terminate in accordance with Section 509.6.1(1)(b), the outdoor portion of the vent shall be enclosed as required by this section for vents not considered to be exposed to the outdoors or such venting shall be engineered."