Straw bales may be used for parapets with a maximum height of two (2) courses. These bales shall be pinned together vertically with rebar and have a continuous wrap with stucco netting encompassing both vertical surfaces and top of the bales. A continuous seal shall be maintained from the roof surface to the top of the parapet and down the other side a minimum of two inches (2") and a maximum of six inches (6"). Reference 14.7.3.15 NMAC and R703 Exterior Coverings for moisture barrier types.

Disclaimer: These regulations may not be the most recent version. New Mexico may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.