New Mexico Administrative Code
Title 14 - HOUSING AND CONSTRUCTION
Chapter 7 - BUILDING CODES GENERAL
Part 2 - 2021 NEW MEXICO COMMERCIAL BUILDING CODE
Section 14.7.2.25 - CHAPTER 17 - SPECIAL INSPECTIONS AND TESTS

Universal Citation: 14 NM Admin Code 14.7.2.25

Current through Register Vol. 35, No. 6, March 26, 2024

See this chapter of the IBC except as provided below.

A. Section 1705.3 - Concrete Construction. See this section of the IBC except as provided below.

(1) Subsection 2 - Delete this section of the IBC and substitute: continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock;

(2) Subsection 3 - Delete this section of the IBC and substitute: nonstructural concrete slabs supported directly on the ground, except pre-stressed slabs-on-grade;

(3) Subsection 4 - Delete this section of the IBC with no substitution.

B. Section 1705.4 - Masonry Construction. See this section of the IBC except delete Exception 2.

C. Section 1705.18 - Fire-resistant penetrations and joints. Delete this section of the IBC and substitute with the following: In buildings three stories or greater, in buildings to Risk Category III and IV, or in fire areas containing Group R occupancies with an occupant load greater than 200, special inspections for through-penetrations, membrane penetration firestops, fire-resistant joint systems and perimeter fire containment systems that are tested and listed in accordance with Sections 714.4.1.2, 714.5.1.2, 715.3.1 and 715.4 shall be in accordance with Section 1705.18.1 or 1705.18.2.

Disclaimer: These regulations may not be the most recent version. New Mexico may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.