New Mexico Administrative Code
Title 14 - HOUSING AND CONSTRUCTION
Chapter 7 - BUILDING CODES GENERAL
Part 2 - 2021 NEW MEXICO COMMERCIAL BUILDING CODE
Section 14.7.2.25 - CHAPTER 17 - SPECIAL INSPECTIONS AND TESTS
Current through Register Vol. 35, No. 18, September 24, 2024
See this chapter of the IBC except as provided below.
A. Section 1705.3 - Concrete Construction. See this section of the IBC except as provided below.
B. Section 1705.4 - Masonry Construction. See this section of the IBC except delete Exception 2.
C. Section 1705.18 - Fire-resistant penetrations and joints. Delete this section of the IBC and substitute with the following: In buildings three stories or greater, in buildings to Risk Category III and IV, or in fire areas containing Group R occupancies with an occupant load greater than 200, special inspections for through-penetrations, membrane penetration firestops, fire-resistant joint systems and perimeter fire containment systems that are tested and listed in accordance with Sections 714.4.1.2, 714.5.1.2, 715.3.1 and 715.4 shall be in accordance with Section 1705.18.1 or 1705.18.2.