New Jersey Administrative Code
Title 8 - HEALTH
Chapter 41 - ADVANCED LIFE SUPPORT SERVICES; MOBILE INTENSIVE CARE PROGRAMS, SPECIALTY CARE TRANSPORT SERVICES AND AIR MEDICAL SERVICES
Subchapter 4 - SPECIFIC VEHICLE AND EQUIPMENT REQUIREMENTS: SCTUS, AMUS AND TRANSPORT-APPROVED MICUS
Section 8:41-4.3 - Vehicle heater/air conditioner

Universal Citation: NJ Admin Code 8:41-4.3

Current through Register Vol. 56, No. 6, March 18, 2024

(a) Each vehicle shall have a functional heater and air conditioner:

1. When the outside temperature is below 65 degrees Fahrenheit, the heater shall, within 20 minutes after initial engine start up, provide an inside ambient patient compartment temperature of 68 to 72 degrees Fahrenheit.

2. The air conditioner shall, within 45 minutes after engine start up, provide an inside ambient patient compartment temperature of:
i. Sixty-eight degrees to 72 degrees Fahrenheit when the outside temperature is between 75 and 85 degrees Fahrenheit; and

ii. At least 13 degrees Fahrenheit below the outside temperature when the outside temperature is over 85 degrees Fahrenheit.

Disclaimer: These regulations may not be the most recent version. New Jersey may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.