New Jersey Administrative Code
Title 7 - ENVIRONMENTAL PROTECTION
Chapter 28 - RADIATION PROTECTION PROGRAMS
Subchapter 42 - RADIO FREQUENCY RADIATION
Section 7:28-42.4 - Radio Frequency Protection Guides (RFPG) for whole body exposure

Universal Citation: NJ Admin Code 7:28-42.4
Current through Register Vol. 56, No. 6, March 18, 2024

Maximum AllowedMaximum AllowedEquivalent
Mean SquaredMean SquaredPlane Wave
FrequencyElectric FieldMagnetic FieldPower Density
RangeStrength (V/m)<2>Strength (A/m)<2>(mW/cm<2>)
300 kHz-3 MHz400,0002.5100
3 MHz-30 MHz4,000 (900/f<2>)0.025 (900/f<2>)900/f<2>
30 MHz-300 MHz4,0000.0251.0
300 MHz-1.5 GHz4,000 (f/300)0.025 (f/300)f/300
1.5 GHz-100 GHz20,0000.1255.0

Note 1. f--frequency (MHz)

Note 2. For near field exposure, both the mean squared electric and magnetic field strengths shall be determined.

Note 3. For frequencies below 300 MHz, both the mean squared electric and magnetic field strengths shall be determined.

Note 4. At frequencies above 300 MHz, either the mean squared electric or magnetic field strengths shall be determined.

Note 5. The applicable RFPG shall be averaged over any 0.1 hour interval.

Note 6. Measurement to determine adherence to the RFPG shall be made at distances 5 cm or greater from any object.

Note 7. Where electromagnetic fields are present at more than one frequency or for broadband fields, the fraction of the RFPG incurred within each frequency interval shall be determined and the sum of all such fractions shall not exceed unity.

Disclaimer: These regulations may not be the most recent version. New Jersey may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.