New Jersey Administrative Code
Title 5 - COMMUNITY AFFAIRS
Chapter 23 - UNIFORM CONSTRUCTION CODE
Subchapter 3 - SUBCODES
Section 5:23-3.4 - Responsibilities
Current through Register Vol. 56, No. 18, September 16, 2024
(a) The enforcement responsibilities of the adopted subcodes are as follows:
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 3 |
Use and Occupancy Classification |
Building/Fire |
Building |
Ch. 4 |
Special Detailed Requirements Based on Use and Occupancy |
||
401.1-402.4 |
Building/Fire |
Building |
|
402.5 |
Fire |
Fire |
|
402.6.1 |
Building/Fire |
Building |
|
402.6.2 #1 |
Building/Fire |
Building |
|
402.6.2 #2 |
Fire |
Fire |
|
402.6.2 #3-#4 |
Building |
Building |
|
402.6.3 |
Building |
Building |
|
402.6.4 |
Building/Fire |
Building |
|
402.7.1-402.7.2 |
Fire |
Fire |
|
402.7.3 |
Fire/Electrical |
Electrical |
|
402.7.4 |
Fire/Electrical |
Fire |
|
402.7.5 |
Building/Fire |
Fire |
|
402.8 |
Building/Fire |
Building |
|
403.1-403.2.1.2 |
Building/Fire |
Building |
|
403.2.2-403.2.3 |
Building |
Building |
|
403.3 |
Fire |
Fire |
|
403.4.1-403.4.7 |
Fire |
Fire |
|
403.4.8 |
Electrical/Fire |
Fire |
|
403.4.8.1 |
Building/Fire |
Building (except system supervision location, which is Fire) |
|
403.4.8.2 |
Building/Fire |
Building |
|
403.4.8.3-403.4.8.4 |
Electrical/Fire |
Electrical |
|
403.5-403.5.2 |
Building/Fire |
Building |
|
403.5.3 |
Building/Fire |
Fire |
|
403.5.4-403.5.5 |
Building/Fire |
Building |
|
403.6 |
Building/Elevator/Fire |
Elevator |
|
403.6.1-403.6.2 |
Building/Elevator/Fire |
Elevator |
|
404.1-404.2 |
Building/Fire |
Building |
|
404.3-404.5 |
Fire |
Fire |
|
404.6 |
Building/Fire |
Building |
|
404.7 |
Fire/Electrical |
Electrical |
|
404.8-404.11 |
Building/Fire |
Building |
|
405.1-405.2 |
Building/Fire |
Building |
|
405.3 |
Fire |
Fire |
|
405.4 |
Building/Fire |
Building |
|
405.5-405.6 |
Fire |
Fire |
|
405.7 |
Building/Fire |
Building |
|
405.8 |
Electrical |
Electrical |
|
405.9 |
Fire |
Fire |
|
406.1-406.2.6 |
Building/Fire |
Building |
|
406.2.7 |
Building/Electrical |
Electrical |
|
406.2.8 |
Building/Fire |
Building |
|
406.2.9 |
Fire |
Fire |
|
406.3-406.3.5 |
Building/Fire |
Building |
|
406.4-406.4.3 |
Building |
Building |
|
406.5.1 |
Building/Fire |
Building |
|
406.5.2 |
Building |
Building |
|
406.5.3-406.5.7 |
Building/Fire |
Building |
|
406.5.8 |
Fire |
Fire |
|
406.5.9 |
Building/Fire |
Building |
|
406.5.10 |
Building |
Building |
|
406.5.11-406.6.1 |
Building/Fire |
Building |
|
406.6.2 |
Building |
Building |
|
406.6.3-406.6.4 |
Fire |
Fire |
|
406.6.4.1 |
Building/Fire |
Building |
|
406.6.4.2-406.7 |
Fire |
Fire |
|
406.7.1 |
Electrical |
Electrical |
|
406.7.2-406.8 |
Building/Fire |
Building |
|
406.8.1 |
Building |
Building |
|
406.8.2-406.8.3 |
Fire |
Fire |
|
407.1-407.2.5 |
Building/Fire |
Building |
|
407.2.6-407.2.7 |
Fire |
Fire |
|
407.3-407.4.4.5#1 and #2 |
Building/Fire |
Building |
|
407.4.4.5#3 |
Building/Fire |
Fire |
|
407.4.4.5.1-407.6 |
Building/Fire |
Building |
|
407.7-407.9 |
Fire |
Fire |
|
407.10 |
Building/Fire |
Building |
|
407.11 |
Electrical |
Electrical |
|
408.1-408.8.4 |
Building/Fire |
Building |
|
408.9-408.11 |
Fire |
Fire |
|
409-410.5.3.5 |
Building/Fire |
Building |
|
410.6-410.7 |
Fire |
Fire |
|
411.1 |
Building/Fire |
Building |
|
411.2-411.4 |
Fire |
Fire |
|
411.5-412.2.2.3.2 |
Building/Fire |
Building |
|
412.2.3-412.2.4 |
Fire |
Fire |
|
412.2.4.1 |
Building/Fire |
Building |
|
412.2.5 |
Building/Electrical |
Building |
|
412.2.6 |
Building |
Building |
|
412.3-412.3.5 |
Building/Fire |
Building |
|
412.3.6-412.3.6.1 |
Fire |
Fire |
|
412.3.6.2-412.4.2 |
Building/Fire |
Building |
|
412.4.3 |
Fire |
Fire |
|
412.4.4 |
As appropriate |
As appropriate |
|
412.4.5-412.5.5 |
Building/Fire |
Building |
|
412.5.6 |
Fire |
Fire |
|
412.5.7 |
Building/Fire |
Building |
|
412.5.8 |
Electrical |
Electrical |
|
412.6-412.7.3 |
Building/Fire |
Building |
|
412.7.4 |
Building/Fire |
Fire |
|
412.7.5 |
Fire |
Fire |
|
413.1 |
Fire |
Fire |
|
413.2 |
Building/Fire |
Building |
|
414.1-414.2 |
Building/Fire |
Fire |
|
414.2.1 |
Building/Fire |
Building |
|
414.2.2-414.2.3 |
Building/Fire |
Fire |
|
414.2.4 |
Building/Fire |
Building |
|
414.2.5-414.5.1 |
Building/Fire |
Fire |
|
414.5.2 |
Electrical |
Electrical |
|
414.5.3 |
Building/Fire |
Fire |
|
414.6 |
Building/Fire |
Building |
|
415.1-415.2 |
Building/Fire |
Building |
|
415.3-415.5 |
Fire |
Fire |
|
415.6-415.8.1 |
Building/Fire |
Building |
|
415.8.2 |
Fire |
Fire |
|
415.8.3-415.8.5 |
Building/Fire |
Building |
|
415.9.1 |
Building/Fire |
Fire |
|
415.9.1.1-415.9.1.2 |
Building/Fire |
Building |
|
415.9.1.3-415.9.1.6 |
Fire |
Fire |
|
415.9.1.7 |
Building/Fire |
Building |
|
415.9.1.8-415.9.2 |
Fire |
Fire |
|
415.9.3-415.10.1 |
Building/Fire |
Fire |
|
415.10.2-415.10.4 |
Building/Fire |
Building |
|
415.11.1-415.11.1.1.2 |
Building/Fire |
Fire |
|
415.11.1.2-415.11.1.7 |
Building/Fire |
Building |
|
415.11.1.8 |
Electrical/Fire |
Electrical |
|
415.11.1.8.1-415.11.3.4 |
Building/Fire |
Building |
|
415.11.4-415.11.5 |
Fire |
Fire |
|
415.11.6-415.11.6.4 |
Building/Fire |
Building/Fire |
|
415.11.6.5 |
Fire |
Fire |
|
415.11.6.6-415.11.6.8 |
Building/Fire |
Building |
|
415.11.6.9 |
Fire |
Fire |
|
415.11.7-415.11.7.2 |
Building/Fire |
Building |
|
415.11.7.3 |
Building/Fire |
Fire |
|
415.11.7.4 |
Building/Fire |
Building |
|
415.11.7.5-415.11.10.3 |
Fire |
Fire |
|
415.11.11-415.11.11.2 |
Electrical/Fire |
Electrical |
|
415.11.12-415.11.12.3 |
Fire |
Fire |
|
416.1-416.3.1 |
Building/Fire |
Building |
|
416.4-416.5 |
Fire |
Fire |
|
417.1-417.3 |
Building |
Building |
|
417.4 |
Fire |
Fire |
|
418 |
Building/Fire |
Building |
|
420.1-420.3 |
Building/Fire |
Building |
|
420.4-420.5 |
Fire |
Fire |
|
420.6-420.7 |
Building/Fire |
Building |
|
420.8-420.10 |
Fire |
Fire |
|
420.11-421.4 |
Building/Fire |
Fire |
|
421.5-421.6 |
Fire |
Fire |
|
421.7 |
Fire/Electrical |
Electrical |
|
422.1-422.3.3 |
Building/Fire |
Building |
|
422.4-422.5 |
Fire |
Fire |
|
422.6 |
Electrical |
Electrical |
|
422.7 |
Fire |
Fire |
|
424.1-424.2 |
Building/Fire |
Building |
|
424.3 |
Fire |
Fire |
|
424.4-424.5 |
Building/Fire |
Building |
|
425.1 |
As applicable |
As applicable |
|
426.1 |
Fire |
Fire |
|
426.1.1-426.1.3 |
Building/Fire |
Building |
|
426.1.4 |
Fire |
Fire |
|
426.1.5-426.1.7 |
Building/Fire |
Building |
|
427.1-427.2.2 |
Building/Fire |
Building |
|
427.2.3 |
Building/Fire |
Fire |
|
428.1-428.3.5 |
Building/Fire |
Building |
|
428.3.6 |
Electrical/Fire |
Electrical |
|
428.3.7-428.3.8 |
Building/Fire |
Building |
|
428.3.9-428.4 |
Building/Fire |
Fire |
|
Ch. 5 |
General Building Heights and Areas |
Building/Fire, except as below: |
Building, except as below |
508.5.7 |
Fire |
Fire |
|
508.5.8-508.5.10 |
Building |
Building |
|
508.5.11 |
Plumbing |
Plumbing |
|
Ch. 6 |
Types of Construction |
Building/Fire |
Building |
Ch. 7 |
Fire and Smoke Protection Systems |
Building/Fire |
Building (Except penetrations in existing membranes for electrical outlets or devices pursuant to Section 714.4.2 which shall be Electrical) |
Ch. 8 |
Interior Finishes |
Building/Fire |
Building |
Ch. 9 |
Fire Protection Systems |
||
901.1-903.3.1.2.3#3.1 |
Fire |
Fire |
|
903.3.1.2.3#3.2-#3.4 |
Building/Fire |
Building |
|
903.3.1.2.3#4-#4.2 |
Fire |
Fire |
|
903.3.1.2.3#4.3-#4.5 |
Building/Fire |
Building |
|
903.3.1.3-904.3 |
Fire |
Fire |
|
904.3.1 |
Electrical |
Electrical |
|
904.3.2-907.2.11.4 |
Fire |
Fire |
|
907.11.5-907.2.11.6 |
Electrical/Fire |
Electrical |
|
907.2.11.7-907.3.2 |
Fire |
Fire |
|
907.3.3 |
Elevator/Fire |
Fire |
|
907.3.4 |
Electrical/Fire |
Electrical |
|
907.4-907.5.2.2.4 |
Fire |
Fire |
|
907.5.2.2.5 |
Electrical/Fire |
Electrical |
|
907.5.2.3-907.6 |
Fire |
Fire |
|
907.6.1-907.6.2 |
Electrical/Fire |
Electrical |
|
907.6.3-909.10.5 |
Fire |
Fire |
|
909.11 |
Electrical/Fire |
Electrical |
|
909.11.1 |
Fire/Building |
Building |
|
909.11.2 |
Electrical/Fire |
Electrical |
|
909.12-909.12.1 |
Fire |
Fire |
|
909.12.2 |
Electrical/Fire |
Electrical |
|
909.12.3-909.19 |
Fire |
Fire |
|
909.20-909.20.7.1 |
Building/Fire |
Building |
|
909.20.7.2 |
Electrical/Fire |
Electrical |
|
909.20.7.3-910.4.5 |
Fire |
Fire |
|
910.4.6 |
Electrical/Fire |
Electrical |
|
910.4.7-911.1.1 |
Fire |
Fire |
|
911.1.2 |
Building/Fire |
Building |
|
911.1.3-913.2 |
Fire |
Fire |
|
913.2.1 |
Building/Fire |
Building |
|
913.3-915.4 |
Fire |
Fire |
|
915.4.1 |
Electrical/Fire |
Electrical |
|
915.4.2-916.3 |
Fire |
Fire |
|
916.4-916.5 |
Electrical/Fire |
Electrical |
|
916.6-918 |
Fire |
Fire |
|
Ch. 10 |
Means of Egress |
||
1001-1007 |
Building/Fire |
Building |
|
1008 |
Building/Electrical/Fire |
Electrical for wiring and function/Building for placement |
|
1009-1009.4 |
Building/Fire |
Building |
|
1009.4.1 |
Electrical/Elevator |
Electrical/Elevator |
|
1009.4.2-1010.2.9.1 |
Building/Fire |
Building |
|
1010.2.9.2 |
Building/Electrical |
Building |
|
1010.2.9.3-1012 |
Building/Fire |
Building |
|
1013 |
Electrical/Fire |
Electrical for wiring and function/Fire for placement |
|
1014-1031 |
Building/Fire |
Building |
|
Ch. 11 |
Accessibility, except that 1110.15, which deals with controls, shall be the responsibility of the person responsible for the control in the general sections of the code |
Building |
Building |
A117.1 |
301.1-308.3.2 |
Building |
Building |
309 |
As applicable |
As applicable |
|
401.1-406.14 |
Building |
Building |
|
407-410 |
Elevator |
Elevator |
|
501.1-506.1 |
Building |
Building |
|
602.1-602.2 |
Building/Plumbing |
Plumbing |
|
602.2.1 |
Building/Plumbing |
Building |
|
602.2.3- 602.4 |
Building/Plumbing |
Plumbing |
|
602.4.1 |
Building/Plumbing |
Building |
|
602.4.2 |
Building/Plumbing |
Plumbing |
|
603.1-603.6 |
Building |
Building |
|
604.1 |
Building/Plumbing |
Building |
|
604.2 |
Building/Plumbing |
Plumbing |
|
604.3 |
Building/Plumbing |
Building |
|
604.4 |
Building/Plumbing |
Plumbing |
|
604.5 |
Building/Plumbing |
Building |
|
604.6 |
Building/Plumbing |
Plumbing |
|
604.7-604.11.1 |
Building/Plumbing |
Building |
|
604.11.2 |
Building/Plumbing |
Plumbing |
|
604.11.3 |
Building/Plumbing |
Building |
|
604.11.4 |
Building/Plumbing |
Plumbing |
|
604.11.5 |
Building/Plumbing |
Building |
|
604.11.6 |
Building/Plumbing |
Plumbing |
|
604.11.7-605.1 |
Building/Plumbing |
Building |
|
605.2 |
Building/Plumbing |
Plumbing |
|
605.3 |
Building/Plumbing |
Building |
|
605.4 |
Building/Plumbing |
Plumbing |
|
606.1-606.2 |
Building/Plumbing |
Building for clear floor space/Plumbing for fixture mounting heights |
|
606.3-606.6 |
Building/Plumbing |
Plumbing |
|
607.1-607.4.2.3 |
Building/Plumbing |
Building |
|
607.5-607.6 |
Building/Plumbing |
Plumbing |
|
607.7 |
Building/Plumbing |
Building |
|
607.8 |
Building/Plumbing |
Plumbing |
|
608.1-608.2 |
Building/Plumbing |
Building for clear floor space/Plumbing for fixture mounting heights |
|
608.2.1.1 |
Building/Plumbing |
Plumbing |
|
608.2.1.2-608.2.2 |
Building/Plumbing |
Building |
|
608.2.2.1 |
Building/Plumbing |
Plumbing |
|
608.2.2.2-608.2.3 |
Building/Plumbing |
Building |
|
608.2.3.1 |
Building/Plumbing |
Plumbing |
|
608.2.3.2-608.3.3 |
Building/Plumbing |
Building |
|
608.4-608.5 |
Building/Plumbing |
Plumbing |
|
608.6-608.7 |
Building/Plumbing |
Building |
|
608.8 |
Building/Plumbing |
Plumbing |
|
609-701.1 |
Building |
Building |
|
702.1 |
Electrical/Fire |
Electrical |
|
703.1-907.1 |
Building |
Building |
|
1009 |
Building |
Building |
|
1101.1-1102.6 |
Building |
Building |
|
1102.7-1102.9 |
As applicable |
As applicable |
|
1102.10 |
Building |
Building |
|
1102.11 |
As applicable |
As applicable |
|
1102.12-1103.6 |
Building |
Building |
|
1103.9 |
As applicable |
As applicable |
|
1103.10 |
Building |
Building |
|
1103.11-1103.11.2.1 |
Building/Plumbing |
Building |
|
1103.11.2.2 |
As applicable |
As applicable |
|
1103.11.2.3-1103.11.2.4 |
Building/Plumbing |
Building |
|
1103.11.2.4.1 |
Building/Plumbing |
Plumbing |
|
1103.11.2.4.2-1103.11.2.4.4 |
Building/Plumbing |
Building |
|
1103.11.2.4.5-1103.11.2.4.6 |
Building/Plumbing |
Plumbing |
|
1103.11.2.5.1-1103.11.2.5.2 |
As applicable |
As applicable |
|
1103.12-1103.12.3.3 |
Building |
Building |
|
1103.12.4-1103.12.4.2 |
Building/Plumbing |
Building |
|
1103.12.4.3-1103.12.4.4 |
Building/Plumbing |
Plumbing |
|
1103.12.5.2-1103.14 |
Building |
Building |
|
1106 |
Building |
Building |
|
Ch. 12 |
Interior Environment |
Building |
Building |
Ch. 14 |
Exterior Walls |
Building |
Building |
Ch. 15 |
Roof Assemblies and Rooftop Structures |
Building |
Building |
Ch. 16 |
Structural Design, except 1612.4 |
Building |
Building |
1612.4 |
Building, except as applicable based on equipment |
Building, except as applicable based on equipment |
|
Ch. 17 |
Structural Tests and Special Inspections |
||
1701.1-1705.18.2 |
Building |
Building |
|
1705.19 |
Fire |
Fire |
|
1705.20 |
Building |
Building |
|
1706.1-1709.7 |
Building |
Building |
|
Ch. 18 |
Soil and Foundations |
Building |
Building |
Ch. 19 |
Concrete |
Building |
Building |
Ch. 20 |
Aluminum |
Building |
Building |
Ch. 21 |
Masonry |
||
2101-2110 |
Building |
Building |
|
2111-2113 |
Building/Fire |
Building |
|
2114 |
Building |
Building |
|
Ch. 22 |
Steel |
Building |
Building |
Ch. 23 |
Wood |
Building |
Building |
Ch. 24 |
Glass and Glazing |
Building |
Building |
Ch. 25 |
Gypsum Board, Gypsum Panel Products, and Plaster |
Building |
Building |
Ch. 26 |
Plastic |
||
2601-2602 |
Building |
Building |
|
2603-2607 |
Building/Fire |
Building |
|
2608-2611 |
Building |
Building |
|
2612-2614 |
Building/Fire |
Building |
|
Ch. 27 |
Electrical 2702.1.1 |
Fire/Electrical |
Electrical |
2702.1.2 |
Building/Fire |
Fire |
|
2702.1.3-2702.1.6 |
Electrical |
Electrical |
|
2702.1.7-2702.1.8 |
Building/Electrical |
Electrical |
|
2702.2 |
As applicable |
As applicable |
|
2702.3 |
Electrical |
Electrical |
|
Ch. 30 |
Elevators and Conveying Systems |
||
3001.1 |
Building/Elevator |
Elevator |
|
3001.3 |
Building for devices not under the scope of the elevator subcode/Elevator for devices under the elevator subcode |
Building for devices not under the scope of the elevator subcode/Elevator for devices under the elevator subcode |
|
3001.4 |
Building/Elevator |
Elevator |
|
3001.5 |
Building/Elevator |
Elevator |
|
3002.1 |
Building/Elevator/Fire |
Building |
|
3002.2 |
Building/Elevator/Fire |
Elevator |
|
3002.3 |
Building/Elevator |
Elevator |
|
3002.4-3002.8 |
Building/Elevator/Fire |
Elevator |
|
3002.9 |
Plumbing/Elevator |
Plumbing for the piping and discharge from the pit/Elevator for the presence of the drain |
|
3003.1 |
Building/Electrical/Elevator |
Elevator |
|
3003.2 |
Building/Elevator/Fire |
Elevator |
|
3003.3 |
Elevator |
Elevator |
|
3004.1 |
Building/Fire for devices not under the scope of the elevator subcode/Elevator for devices under the elevator subcode |
Building for devices not under the scope of the elevator subcode/Elevator for devices under the elevator subcode |
|
3004.2 |
Building/Elevator/Fire |
Elevator |
|
3004.2.1 |
Building/Elevator/Fire |
Building |
|
3004.2.2 |
Elevator |
Elevator |
|
3004.3-3004.4 |
Building/Fire |
Building |
|
3005.1 |
Building/Elevator/Fire |
Building |
|
3005.2 |
Building/Elevator |
Elevator |
|
3005.3 |
Elevator/Fire |
Fire |
|
3005.4 |
Building/Elevator |
Building |
|
3005.5 |
Fire/Electrical/Elevator |
Elevator |
|
3005.6 |
Elevator/Plumbing |
Elevator |
|
3006.1-3006.4 |
Building/Fire |
Building |
|
3007.1 |
Elevator/Fire |
Elevator |
|
3007.2 |
Fire |
Fire |
|
3007.3 |
Building/Elevator |
Building |
|
3007.4 |
Elevator/Fire |
Elevator |
|
3007.5-3007.5.1 |
Building/Fire |
Building |
|
3007.5.2 |
Building/Electrical/Elevator/Fire |
Electrical for wiring and function/Elevator for placement |
|
3007.6-3007.6.4 |
Building/Fire |
Building |
|
3007.6.5 |
Elevator/Fire |
Elevator |
|
3007.7 |
Elevator/Fire |
Fire |
|
3007.8 |
Electrical |
Electrical |
|
3007.8.1 |
Building/Electrical |
Electrical |
|
3007.9 |
Fire |
Fire |
|
3008.1-3008.1.2 |
Building/Fire |
Building |
|
3008.1.3 |
Fire |
Fire |
|
3008.1.4 |
Elevator/Fire |
Elevator |
|
3008.2-3008.2.2 |
Fire |
Fire |
|
3008.3 |
Building/Elevator |
Building |
|
3008.4 |
Elevator/Fire |
Elevator |
|
3008.5-3008.6.5 |
Building/Fire |
Building |
|
3008.6.6 |
Fire |
Fire |
|
3008.7 |
Elevator/Fire |
Fire |
|
3008.8 |
Electrical |
Electrical |
|
3008.8.1-3008.8.2 |
Building/Electrical |
Electrical |
|
3008.9 |
Fire |
Fire |
|
3008.10 |
Building/Fire |
Building |
|
Ch. 31 |
Special Construction 3101-3102.3.1 |
Building |
Building |
3102.4-3102.6.1.1 |
Building/Fire |
Building |
|
3102.7-3102.8.1.2 |
Building |
Building |
|
3102.8.2 |
Building/Electrical |
Electrical |
|
3102.8.3-3103.2 |
Building |
Building |
|
3103.3-3104.10 |
Building/Fire |
Building |
|
3105.1- 3108.2 |
Building |
Building |
|
3109 |
See below for ISPSC |
See below for ISPSC |
|
ISPSC, Section 305 |
Building |
Building (Except safety covers pursuant to Section 305.1 which shall be Electrical) |
|
ISPSC, Section 310 (APSP/ICC 7) |
Plumbing |
Plumbing |
|
ISPSC, Section 311.9 |
Plumbing |
Plumbing |
|
ISPSC, Section 324, except as below |
Building/Fire |
Building |
|
ISPSC, Section 324.2 |
Building/Fire (except for the hose bibb and backflow preventer, which shall be plumbing) |
Building (except for the hose bibb and backflow preventer, which shall be plumbing) |
|
ISPSC, Section 324.4 |
Electrical |
Electrical |
|
3110 |
Electrical |
Electrical |
|
3111.1 |
Building |
Building |
|
3111.2 |
Building/Fire/Plumbing |
Plumbing |
|
3111.3.1 |
Electrical |
Electrical |
|
3111.3.2 |
Building |
Building |
|
3111.3.3 |
Building |
Building |
|
3111.3.4 |
Fire |
Fire |
|
3111.3.5 |
Building/Fire |
Building |
|
3112 |
Building |
Building |
|
3115 |
Building |
Building |
|
Ch. 32 |
Encroachments into the Public-Right-of-Way |
Building |
Building |
Ch. 33 |
Safeguards during Construction |
||
3301 |
Building |
Building |
|
3302.1 |
As applicable |
As applicable |
|
3302.2 |
Building |
Building |
|
3302.3 |
Fire |
Fire |
|
3303.1-3303.5 |
Building |
Building |
|
3303.6 |
As applicable |
As applicable |
|
3303.7 |
Fire |
Fire |
|
3304-3308 |
Building |
Building |
|
3309 |
Fire |
Fire |
|
3310 |
Building/Fire |
Building |
|
3311-3313 |
Fire |
Fire |
|
Appx H |
Signs |
Building except for H106 |
Building except for H106 |
H106 |
Electrical |
Electrical |
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 1 |
Definitions |
Plumbing |
Plumbing |
Ch. 2 |
General Regulations |
Plumbing |
Plumbing |
Ch. 3 |
Materials |
Plumbing |
Plumbing |
Ch. 4 |
Joints and Connections |
Plumbing |
Plumbing |
Ch. 5 |
Traps, Cleanouts and Backwater Valves |
Plumbing |
Plumbing |
Ch. 6 |
Liquid Waste Treatment Equipment |
Plumbing |
Plumbing |
Ch. 7 |
Plumbing Fixtures, Fixture Fittings and Plumbing Appliances |
Plumbing |
Plumbing |
Ch. 8 |
Hangers and Supports |
Plumbing |
Plumbing |
Ch. 9 |
Indirect Waste Piping and Special Wastes |
Plumbing |
Plumbing |
Ch. 10 |
Water Supply and Distribution |
Plumbing (except 10.5.9) |
Plumbing |
10.5.9 |
Fire/Plumbing |
Plumbing (except dedicated fire service supply) Fire (dedicated fire service supply) |
|
Ch. 11 |
Sanitary Drainage Systems |
Plumbing |
Plumbing |
Ch. 12 |
Vents and Venting |
Plumbing |
Plumbing |
Ch. 13 |
Storm Water Drainage |
Plumbing |
Plumbing |
Ch. 14 |
Special Requirements for Health Care Facilities |
Plumbing |
Plumbing |
Ch. 15 |
Tests and Maintenance |
Plumbing |
Plumbing |
Ch. 16 |
Regulations Governing Individual Sewage Disposal Systems for Homes and Other Establishments Where Public Sewage Systems Are Not Available. |
Plumbing |
Plumbing |
Ap. B |
Sizing the Building Water Supply and Distribution Piping System |
Plumbing |
Plumbing |
Ap. C |
Conversions: Metric to U.S. Customary Units |
Plumbing |
Plumbing |
Ap. D |
Determining the Minimum Number of Required Plumbing Fixtures |
Plumbing |
Plumbing |
Ap. E |
Special Design Plumbing Systems |
Plumbing |
Plumbing |
Ap. F |
Requirements of the Adopting Agency |
Plumbing |
Plumbing |
Ap. H |
Combined Building Drain and Building Sewers |
Plumbing |
Plumbing |
Ap. I |
Flow in Horizontal Sanitary Drain Piping |
Plumbing |
Plumbing |
Ap. J |
An Acceptable Brazing Procedure for General Plumbing |
Plumbing |
Plumbing |
Ap. K |
Converting Water Supply Fixture Units (WSFU) to Gallons Per Minute Flow (GPM) |
Plumbing |
Plumbing |
Ap. L |
Tiny Houses N.J.A.C. 5:23-3.15(c) Automatic Rain Sensor Device |
Plumbing Electrical/Plumbing<1> |
Plumbing Electrical/Plumbing<1> |
Note 1: Where the device is wireless and plugged into an existing receptacle, plan review and inspection shall be plumbing; otherwise, electrical.
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Article 90 |
Introduction |
Electrical |
Electrical |
Ch. 1 |
General |
Electrical |
Electrical |
Ch. 2 |
Wiring and Protection 200.1-250.50 |
Electrical |
Electrical |
250.52(A)1-2 |
Electrical |
Electrical |
|
250.52(A)3 |
Electrical/Building |
Building |
|
250.52(A)4-250.102(E) |
Electrical |
Electrical |
|
250.104(A)(1) |
Electrical |
Electrical (except gas water heater replacements) Plumbing (gas water heater replacements only) |
|
250.104(A)(2)-285 |
Electrical |
Electrical |
|
Ch. 3 |
Wiring Methods and Materials 300.1 to 300.20 |
Electrical |
Electrical |
300.21 |
Electrical/Fire |
Electrical |
|
300.22-399 |
Electrical |
Electrical |
|
Ch. 4 |
Equipment for General Use 400-450.28 |
Electrical |
Electrical |
450.41-450.48 |
Electrical/Fire |
Electrical |
|
455-490 |
Electrical |
Electrical |
|
Ch. 5 |
Special Occupancies |
Electrical/Fire |
Electrical |
Ch. 6 |
Special Equipment 600-610 |
Electrical |
Electrical |
620.1-620.12 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.13 |
Electrical/Elevator<1> |
Electrical<2> (on the line side of the disconnect) Elevator<2> (on the load side of the disconnect) Electrical<3> |
|
620.14-620.21 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.22 |
Electrical/Elevator<1> |
Electrical<2> (on the line side of the disconnect) Elevator<2 >(on the load side of the disconnect) Electrical<3> |
|
620.23-620.24 |
Electrical/Elevator<1> |
Electrical |
|
620.25-620.37 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.38 |
Electrical/Elevator<1> |
Electrical |
|
620.41-620.44 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.51-620.51(A) |
Electrical/Elevator<1> |
Electrical |
|
620.51(B)-(D) |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.52 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.53-620.55 |
Electrical/Elevator<1> |
Electrical<2> (on the line side of the disconnect) Elevator<2> (on the load side of the disconnect) Electrical<3> |
|
620.61(A)-(B) |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.61(C)-(D) |
Electrical/Elevator<1> |
Electrical<2> (on the line side of the disconnect) Elevator<2> (on the load side of the disconnect) Electrical<3> |
|
620.62-620.84 |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.85 (except for cartop receptacle(s)) |
Electrical/Elevator<1> |
Elevator/Electrical<2>(car top receptacle only) |
|
620.91(A) & (C) |
Electrical/Elevator<1> |
Elevator/Electrical<3> |
|
620.91(B) |
Electrical/Elevator<1> |
Electrical |
|
625-694 |
Electrical |
Electrical |
|
695 |
Electrical/Fire |
Electrical |
|
Ch. 7 |
Special Conditions 700-727 |
Electrical |
Electrical |
728 |
Fire/Electrical |
Electrical |
|
750 |
Electrical |
Electrical |
|
760 |
Electrical/Fire |
Electrical |
|
770 |
Electrical |
Electrical |
|
Ch. 8 |
Communication Systems |
Electrical |
Electrical |
Ch. 9 |
Tables |
Electrical |
Electrical |
Note 1: Joint with Elevator Subcode Official for N.J.A.C. 5:23-12 devices not installed in Group R-3, R-4 or R-5 or in structures of Group R-2 in which the elevator devices are wholly within dwelling units and are not accessible to the general public.
Note 2: The following sections are enforced by the Electrical inspector when devices covered by N.J.A.C. 5:23-12 are installed in any building excluding installations in Group R-3, R-4 or R-5 or in structures of Group R-2 where the elevator devices are located wholly within the dwelling units and are not accessible to the general public.
Note 3: Inspection responsibility for this section shall be the electrical inspector when devices are installed in buildings of Group R-3, R-4 or R-5 or in buildings of Group R-2 where the elevator devices are located wholly within dwelling units and not accessible to the general public.
International Energy Conservation Code--Residential
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 1 (RE) |
Scope and Administration |
As applicable |
As applicable |
Ch. 3 (RE) |
General Requirements |
Building |
Building |
Ch. 4 (RE) |
Residential Energy Efficiency |
||
R401 |
Building |
Building |
|
R402 (except R402.4.5-R402.4.6) |
Building |
Building |
|
R402.4.5-R402.4.6 |
Electrical |
Electrical |
|
R403.1 |
Electrical |
Electrical |
|
R403.2 |
Plumbing |
Plumbing |
|
R403.3 |
Building |
Building |
|
R403.4 |
Plumbing |
Plumbing |
|
R403.5.1.1 -- Pump with integrated switch |
Plumbing |
Plumbing |
|
R403.5.1.1 -- Pump with non-integrated switch |
Electrical |
Electrical |
|
R403.5.1.2 |
Electrical |
Electrical |
|
R403.5.2- R403.5.3 |
Plumbing |
Plumbing |
|
R403.6 |
Building |
Building |
|
R403.7 |
Plumbing |
Plumbing |
|
R403.8 |
As applicable |
As applicable |
|
R403.9 |
Electrical |
Electrical |
|
R403.10.1 - Switch |
Electrical |
Electrical |
|
R403.10.1 - Gas Heater, Pilot |
Plumbing |
Plumbing |
|
R403.10.2-R403.12 |
Electrical |
Electrical |
|
R404.1-R404.1.1 |
Electrical |
Electrical |
|
R404.1.2 |
Plumbing |
Plumbing |
|
R404.2-R404.3 |
Electrical |
Electrical |
|
R405-R406 |
As applicable |
As applicable |
|
R408 |
Building/Plumbing, |
Building/Plumbing |
|
as applicable |
as applicable |
||
Appx. |
Solar-Ready |
As applicable |
As applicable |
RB |
Provisions--Detached One- and Two-Family Dwellings |
||
Appx. |
Zero Energy Residential |
As applicable |
As applicable |
RC |
Building Provisions |
International Energy Conservation Code--Commercial, adopted via ASHRAE Standard 90.1
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 4 |
Administration and Enforcement |
As applicable |
As applicable |
Ch. 5 |
Building Envelope |
Building |
Building |
Ch. 6 |
Heating, Ventilating, and Air Conditioning |
As applicable except as below: |
As applicable except as below: |
6.4.4.1.1-6.4.4.1.2 |
Building |
Building |
|
6.4.4.1.3 |
Plumbing |
Plumbing |
|
6.4.4.1.4-6.4.4.1.5 |
Building |
Building |
|
6.4.4.2 |
Building |
Building |
|
Ch. 7 |
Service Water Heating |
As applicable |
As applicable |
Ch. 8 |
Power |
Electrical |
Electrical |
Ch. 9 |
Lighting |
Electrical |
Electrical |
Ch. 10 |
Other Equipment 10.4.1 |
Electrical |
Electrical |
10.4.2 |
Plumbing |
Plumbing |
|
10.4.3-10.4.4 |
Elevator |
Elevator |
|
10.4.5 |
Building |
Building |
|
10.4.7 |
Plumbing |
Plumbing |
|
Ch. 11 |
Energy Cost Budget Method |
As applicable |
As applicable |
Appx. |
Solar-Ready |
As applicable |
As applicable |
CB |
Zone--Commercial |
||
Appx.CC |
Zero Energy Commercial Building Provisions |
As applicable |
As applicable |
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 3 |
General Regulations |
||
301.2 |
Building |
Building |
|
301.3-301.5 |
Plumbing |
Plumbing |
|
301.6 |
Fire/Plumbing for fuel gas piping |
Fire/Plumbing for fuel gas piping |
|
301.7-301.9 |
Fire |
Fire |
|
301.10 |
Electrical |
Electrical |
|
301.11 |
Plumbing |
Plumbing |
|
301.12 |
Fire |
Fire |
|
301.13-301.18 |
Building |
Building |
|
301.19 |
Electrical (switch)/Plumbing (valve) |
Electrical (switch)/Plumbing (valve) |
|
302 |
Building |
Building |
|
303-304.10 |
Fire |
Fire |
|
304.11 |
Building/Fire |
Building |
|
304.12 |
Fire |
Fire |
|
305 |
Plumbing |
Plumbing |
|
306.1-306.3 |
Building |
Building |
|
306.3.1 |
Electrical |
Electrical |
|
306.4 |
Building |
Building |
|
306.4.1 |
Electrical |
Electrical |
|
306.5-306.5.1 |
Building |
Building |
|
306.5.2 |
Electrical |
Electrical |
|
307 |
Plumbing |
Plumbing |
|
308 |
Building/Fire |
Fire |
|
309 |
Building |
Building |
|
310-311 |
Building/Fire |
Fire |
|
312 |
Plumbing |
Plumbing |
|
Ch. 4 |
Ventilation |
Building |
Building |
Ch. 5 |
Exhaust Systems 501 |
Building |
Building |
502 |
Building/Fire |
Building |
|
503 |
Building/Fire |
Fire |
|
504 |
Building/Fire |
Building |
|
505-510 |
Building/Fire |
Fire |
|
511 |
Building/Fire |
Fire |
|
512 |
Building |
Building |
|
513.1- 513.10.5 |
Fire |
Fire |
|
513.11-513.11.1 |
Building/Electrical/Fire |
Electrical (except rated enclosures, which are Building) |
|
513.11.2 |
Electrical/Fire |
Electrical |
|
513.12-513.12.1 |
Fire |
Fire |
|
513.12.2 |
Fire/Electrical |
Electrical |
|
513.12.3-513.19 |
Fire |
Fire |
|
514 |
Building |
Building |
|
Ch. 6 |
Duct Systems |
||
601-602.2.1.6 |
Building/Fire |
Building |
|
602.2.1.7 |
Building/Fire/Plumbing |
Plumbing |
|
602.2.1.8-603.1 |
Building/Fire |
Building |
|
603.2 |
Building |
Building |
|
603.3-605 |
Building/Fire |
Building |
|
606 |
Building/Fire |
Fire |
|
607 |
Building/Fire |
Building |
|
608 |
Building |
Building |
|
Ch. 7 |
Combustion Air |
Fire |
Fire |
Ch. 8 |
Chimneys and Vents |
Building/Fire |
Fire (except 801.3 and 801.13) |
801.3 and 801.13 |
Building/Fire |
Building |
|
Ch. 9 |
Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment |
||
901.1-908.4 |
Building/Fire |
Building |
|
908.5-908.6 |
Plumbing |
Plumbing |
|
908.7 |
Plumbing/Fire |
Plumbing |
|
908.8 |
Building/Plumbing |
Plumbing |
|
909-910 |
Building/Fire |
Fire |
|
911-914 |
Building/Fire |
Building |
|
915 |
Fire |
Fire |
|
916 |
Electrical/Plumbing |
Electrical if electric/Plumbing if oil fired |
|
917 |
Fire |
Fire |
|
918 |
Building/Fire |
Building |
|
919 |
Plumbing |
Plumbing |
|
920-923 |
Building/Fire |
Building |
|
924 |
Fire |
Fire |
|
925 |
Building/Fire |
Building |
|
926 |
See Chapter 7 of the International Fuel Gas Code |
See Chapter 7 of the International Fuel Gas Code |
|
927 |
Electrical |
Electrical |
|
928 |
Building/Plumbing |
Plumbing |
|
929 |
Building/Fire |
Building |
|
930 |
Electrical/Fire |
Electrical |
|
Ch. 10 |
Boilers, Water Heaters and Pressure Vessels |
Plumbing |
Plumbing |
Ch. 11 |
Refrigeration |
||
1101.1-1101.1.2 |
Fire/Plumbing |
Plumbing |
|
1101.2 |
Plumbing |
Plumbing |
|
1101.3 |
Building |
Building |
|
1101.4-1101.5 |
Plumbing |
Plumbing |
|
1101.7 |
Plumbing |
Plumbing |
|
1101.8 |
Fire |
Fire |
|
1101.9 |
Plumbing |
Plumbing |
|
1102-1103 |
Plumbing |
Plumbing |
|
1104.1 |
Plumbing |
Plumbing |
|
1104.2-1104.4 |
Building/Fire |
Fire |
|
1105.1-1105.2 |
Building |
Building |
|
1105.3-1105.5 |
Fire |
Fire |
|
1105.6 |
Building |
Building |
|
1105.7 |
Plumbing |
Plumbing |
|
1105.8-1105.9 |
Building/Fire |
Building |
|
1106 |
Fire |
Fire |
|
1107-1111 |
Plumbing |
Plumbing |
|
Ch. 12 |
Hydronic Piping |
Plumbing |
Plumbing |
Ch. 13 |
Fuel Oil Piping and Storage |
||
1301.1-1301.2 |
Fire/Plumbing |
Fire (storage systems) Plumbing (Piping systems) |
|
1301.3 |
Fire |
Fire |
|
1301.4 |
Fire/Plumbing |
Fire (storage systems) Plumbing (Piping systems) |
|
1301.5 |
Fire |
Fire |
|
1302-1305 |
Plumbing |
Plumbing |
|
1306 |
Fire |
Fire |
|
1307-1308 |
Plumbing |
Plumbing |
|
Ch. 14 |
Solar Thermal Systems |
||
1401.2-1401.4 |
Plumbing |
Plumbing |
|
1402.1-1402.2 |
Building |
Building |
|
1402.3-1402.5 |
Plumbing |
Plumbing |
|
1402.6-1402.8.2 |
Building |
Building |
|
1402.8.3-1402.8.7 |
Plumbing |
Plumbing |
|
1403 |
Plumbing/Fire |
Plumbing |
|
1404 |
Plumbing |
Plumbing |
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 3 |
Building |
||
Planning |
|||
R300 |
Building/Fire |
Building |
|
R301 |
Building |
Building |
|
R302 |
Building/Fire |
Building (Except penetrations in existing membranes for electrical outlets or devices pursuant to Section 302.4 through 302.4.2 which shall be Electrical) |
|
R303-R306 |
Building |
Building |
|
R307.1 |
Plumbing |
Plumbing |
|
R307.2-R309.3 |
Building |
Building |
|
R309.4 |
Electrical |
Electrical |
|
R309.5 |
Fire |
Fire |
|
R310-R311 |
Building/Fire |
Building |
|
R312 |
Building/Fire |
Building |
|
< |
R313 |
Fire< 2> |
Fire< 2> |
> |
R314-R314.5 |
Fire |
Fire |
R314.6 |
Electrical/Fire |
Electrical |
|
R314.7-R315.5 |
Fire |
Fire |
|
R315.6 |
Electrical/Fire |
Electrical |
|
R315.7 |
Fire |
Fire |
|
R316 |
Building/Fire |
Building |
|
R317-R318 |
Building |
Building |
|
R319 |
Fire |
Fire |
|
R321.1-R321.2 |
Elevator |
Elevator |
|
R321.3 |
Building |
Building |
|
R322, except R322.1.6 |
Building |
Building |
|
R322.1.6 |
As applicable based on equipment |
As applicable based on equipment |
|
R324.2 |
Building/Fire/Plumbing |
Plumbing |
|
R324.3 |
Electrical |
Electrical |
|
R324.4-R324.5 |
Building |
Building |
|
R324.6 |
Fire |
Fire |
|
R324.7 |
Building/Fire |
Building |
|
R324.7.1 |
Building/Fire |
Building |
|
R325 |
Building/Fire |
Building |
|
R327 |
See below for ISPSC |
See below for ISPSC |
|
ISPSC, Section 305 |
Building |
Building (except for safety covers pursuant to Section 305.1, Exception 1, which shall be Electrical) |
|
ISPSC, Section 310 (APSP/ICC 7) |
Plumbing |
Plumbing |
|
ISPSC, Section 311.9 |
Plumbing |
Plumbing |
|
ISPSC, Section 324, except as below |
Building/Fire |
Building |
|
ISPSC, Section 324.2 |
Building/Fire (except for the hose bibb and backflow preventer, which shall be plumbing) |
Building (except for the hose bibb and backflow preventer, which shall be plumbing) |
|
ISPC, Section 324.4 |
Electrical |
Electrical |
|
R328.1-R328.6 |
Electrical |
Electrical |
|
R328.7-R328.8 |
Fire |
Fire |
|
R328.9 |
Electrical/Fire |
Fire |
|
R328.10-R328.11 |
Electrical |
Electrical |
|
R329 |
Electrical |
Electrical |
|
R330 |
Electrical/Fire |
Fire |
|
Ch. 4 |
Foundations |
Building |
Building |
Ch. 5 |
Floors |
Building |
Building |
Ch. 6 |
Wall Construction |
Building |
Building |
Ch. 7 |
Wall Covering |
Building |
Building |
Ch. 8 |
Roof-Ceiling Construction |
Building |
Building |
Ch. 9 |
Roof Assemblies, except R905.16-R905.17 and R907.1 |
Building |
Building |
R905.16-R905.17 |
Building/Electrical |
Building |
|
R907.1 |
As applicable |
As applicable |
|
Ch. 10 |
Chimneys and Fireplaces |
Building/Fire |
Building |
Ch. 11 |
Energy Efficiency |
||
N1101.1-N1101.5.1 |
As applicable |
As applicable |
|
N1101.7-N1101.12 |
Building |
Building |
|
N1101.13-N1101.14 |
Building |
Building |
|
N1102.1-N1102.4.4 |
Building |
Building |
|
N1102.4.5-N1102.4.6 |
Electrical |
Electrical |
|
N1102.5 |
Building |
Building |
|
N1103.1 |
Electrical |
Electrical |
|
N1103.2 |
Plumbing |
Plumbing |
|
N1103.3 |
Building |
Building |
|
N1103.4 |
Plumbing |
Plumbing |
|
N1103.5.1.1 -pump with integrated switch |
Plumbing |
Plumbing |
|
N1103.5.1.1 -pump with non-integrated switch |
Electrical |
Electrical |
|
N1103.5.1.2 |
Electrical |
Electrical |
|
N1103.5.2-N1103.5.3 |
Plumbing |
Plumbing |
|
N1103.6 |
Building |
Building |
|
N1103.7 |
Plumbing |
Plumbing |
|
N1103.8 |
As applicable |
As applicable |
|
N1103.9 |
Electrical |
Electrical |
|
N1103.10.1 -Switch |
Electrical |
Electrical |
|
N1103.10.1 -Gas Heater, Pilot |
Plumbing |
Plumbing |
|
N1103.10.2 -N1103.12 |
Electrical |
Electrical |
|
N1104.1-N1104.1.1 |
Electrical |
Electrical |
|
N1104.1.2 |
Plumbing |
Plumbing |
|
N1104.2-N1104.3 |
Electrical |
Electrical |
|
N1105-N1106 |
As applicable |
As applicable |
|
N1108 |
Building/Plumbing, as applicable |
Building/Plumbing, as applicable |
|
Ch. 13 |
General |
||
Mechanical System Requirements |
|||
M1301 |
Plumbing |
Plumbing |
|
M1302 |
Fire/Plumbing |
Plumbing |
|
M1303 |
Electrical/Plumbing |
Plumbing |
|
M1304 |
Fire/Plumbing |
Plumbing |
|
M1305-M1305.1.2 |
Building |
Building |
|
M1305.1.2.1 |
Electrical |
Electrical |
|
M1305.1.3 |
Plan Review and Field Inspection for access, passageways, and service clearances for appliances shall be the responsibility of the subcode with plan review and inspection responsibility for the appliance |
||
M1306.1 |
Fire |
Fire |
|
M1306.2-M1306.2.3 |
Building/Fire |
Fire |
|
M1307.1 |
Fire |
Fire |
|
M1307.2 |
Building |
Building |
|
M1307.3-M1307.4.3 |
Fire |
Fire |
|
M1307.5 |
Electrical |
Electrical |
|
M1307.6 |
Plumbing |
Plumbing |
|
M1307.7 |
Responsibility of the subcode with plan review and inspection responsibility for the appliance |
Responsibility of the subcode with plan review and inspection responsibility for the appliance |
|
M1307.8 |
Electrical (switch)/Plumbing (valve) |
Electrical (switch)/Plumbing (valve) |
|
Ch. 14 |
Heating and Cooling Equipment |
||
M1401.1-M1401.3 |
Plumbing |
Plumbing |
|
M1401.4 |
Building/Plumbing |
Plumbing, except for proper support of the equipment, which is Building |
|
M1401.5 |
Building/Plumbing |
Plumbing |
|
M1402.1-M1402.3 |
Electrical for electric appliances/Plumbing for oil-fired appliances |
Electrical for electric appliances/Plumbing for oil-fired appliances |
|
M1403.1 |
Electrical |
Electrical |
|
M1404.1 |
Plumbing |
Plumbing |
|
M1405-M1406.5 |
Electrical |
Electrical |
|
M1407.1-M1407.4 |
Building/Fire |
Building |
|
M1407.5 |
Electrical |
Electrical |
|
M1408-M1410 |
Building/Fire |
Fire |
|
M1411-M1413 |
Plumbing |
Plumbing |
|
M1414 |
Building/Fire |
Fire |
|
M1415 |
Building/Fire |
Building |
|
Ch. 15 |
Exhaust Systems |
||
M1501-M1502 |
Building/Fire |
Building |
|
M1503 |
Building/Fire |
Fire |
|
M1504 |
Building |
Building |
|
M1505 |
Building |
Building |
|
Ch. 16 |
Duct Systems |
||
M1601.1 |
Building |
Building |
|
M1601.1.1-M1601.6 |
Building/Fire |
Building |
|
M1602 |
Building/Fire |
Building |
|
Ch. 17 |
Combustion Air |
Fire |
Fire |
Ch. 18 |
Chimneys and Vents |
||
M1801-M1804 |
Building/Fire |
Fire for labeled vents and factory-built chimneys/Building for masonry chimneys |
|
M1805 |
Building/Fire (Masonry Chimneys) Building/Fire (Factory-built chimneys) |
Building (Masonry Chimneys) Fire (Factory-Built chimneys) |
|
Ch. 19 |
Special Fuel-Burning Equipment |
||
M1901 |
Building/Fire |
Fire |
|
M1902.1-M1902.2 |
Building |
Building |
|
M1902.3 |
Fire |
Fire |
|
M1902.4 |
Building |
Building |
|
M1903-M1904 |
Building/Fire |
Fire |
|
Ch. 20 |
Boilers/Water Heaters |
Plumbing |
Plumbing |
Ch. 21 |
Hydronic Piping, except |
Plumbing |
Plumbing |
M2101.6 |
|||
M2101.6 |
Building/Plumbing |
Building |
|
Ch. 22 |
Special Piping and Storage Systems |
||
M2201 |
Fire |
Fire |
|
M2201.3 |
Building/Fire/Plumbing |
Building |
|
M2202-M2204 |
Plumbing |
Plumbing |
|
Ch. 23 |
Solar Systems |
||
M2301.2.1-M2301.2.2 |
Building |
Building |
|
M2301.2.3-M2301.5 |
Plumbing |
Plumbing |
|
M2301.6 |
Building |
Building |
|
M2301.7-M2301.7.2 |
Plumbing |
Plumbing |
|
Ch. 24 |
Fuel Gas |
||
G2404.2-G2404.3 |
Fire |
Fire |
|
G2404.4-2404.9 |
Building |
Building |
|
G2404.10-G2404.11 |
Plumbing |
Plumbing |
|
G2405 |
Building |
Building |
|
G2406 |
Plumbing |
Plumbing |
|
G2407-G2409 |
Fire |
Fire |
|
G2410 |
Electrical |
Electrical |
|
G2411 |
Plumbing/Electrical |
Plumbing-except when bonded to electrical service equipment, then Electrical |
|
G2412-G2424 |
Plumbing |
Plumbing |
|
G2425.1-G2425.2 |
Building/Fire |
Fire |
|
G2425.3 |
Building/Fire |
Building |
|
G2425.4-G2425.6 |
Building/Fire |
Fire |
|
G2425.7 |
Building/Fire |
Building |
|
G2425.8-G2425.10 |
Building/Fire |
Fire |
|
G2425.11 |
Building/Fire |
Building |
|
G2425.12-G2425.15.1 |
Building/Fire |
Fire |
|
G2425.15.2 |
Fire |
Fire |
|
G2425.15.3 |
Building/Fire |
Building |
|
G2425.15.4-G2427.5.1 |
Building/Fire |
Fire |
|
G2427.5.2 |
Building/Fire |
Building |
|
G2427.5.3-G2427.5.6.4 |
Building/Fire |
Fire |
|
G2427.5.7 |
Building |
Building |
|
G2427.5.9 |
Building/Fire |
Fire |
|
G2427.5.10 |
Building/Fire |
Fire |
|
G2427.6-G2427.8 |
Building/Fire |
Fire |
|
G2427.9 |
Plumbing |
Plumbing |
|
G2427.10.1-G2430.1 |
Building/Fire |
Fire |
|
G2430.2 |
Building/Fire |
Building |
|
G2432-G2434 |
Plumbing/Fire |
Plumbing |
|
G2435 |
Plumbing/Fire |
Fire |
|
G2436-G2440.3 |
Building/Fire |
Building |
|
G2440.4-2440.5 |
Building/Fire |
Fire |
|
G2440.6-2440.7 |
Building/Fire |
Building |
|
G2441 |
Plumbing |
Plumbing |
|
G2442 |
Building/Fire |
Building |
|
G2443 |
Plumbing |
Plumbing |
|
G2444-G2446 |
Building/Fire |
Building |
|
G2447 |
Fire |
Fire |
|
G2448-G2449.3 |
Plumbing |
Plumbing |
|
G2449.4-2450.3 |
Building/Fire |
Building |
|
G2450.4 |
Plumbing |
Plumbing |
|
G2451 |
Building/Fire |
Building |
|
G2452-G2453 |
Fire/Plumbing |
Plumbing |
|
Ch. 29 |
Water Supply and Distribution<2> |
||
P2904.1 |
Plumbing/Fire |
Plumbing |
|
P2904.1.1-P2904.2.2 |
Fire |
Fire |
|
P2904.2.3 |
Plumbing |
Plumbing |
|
P2904.2.4-P2904.2.6 |
Fire |
Fire |
|
P2904.3-P2904.3.3 |
Plumbing |
Plumbing |
|
P2904.3.4 |
Fire/Plumbing |
Plumbing |
|
P2904.4 |
Fire/Plumbing |
Fire |
|
P2904.5-P2904.6 |
Fire/Plumbing |
Plumbing |
|
P2904.7 |
Fire/Plumbing |
Fire |
|
P2904.8.1 #1 |
Fire |
Fire |
|
P2904.8.1 #2 |
Fire |
Fire |
|
P2904.8.1 #3 |
Fire |
Fire |
|
P2904.8.1 #4 -#6 |
Fire/Plumbing |
Plumbing |
|
P2904.8.1 #7 and #8 |
Plumbing |
Plumbing |
|
P2904.8.2 #1 |
Fire |
Fire |
|
P2904.8.2 #2 -#4 |
Fire/Plumbing |
Fire |
|
Appx AH |
Patio Covers |
Building |
Building |
Appx AK |
Sound Transmission |
Building |
Building |
Appx AQ |
Tiny Homes |
Building/Fire (except that for AQ106, responsibility shall be as applicable) |
Building (except that for AQ106, responsibility shall be as applicable) |
Appx AS |
Strawbale Construction |
Building |
Building |
Appx AT |
Solar-Ready Provisions--Detached One- and Two-Family Dwellings and Townhouses |
As applicable |
As applicable |
Appx AU |
Cob Construction (Monolithic Adobe) |
Building |
Building |
Appx AW |
3D-Printed Building Construction |
Building |
Building |
Chapter |
Section/Title |
Responsibility Plan Review |
Inspection |
Ch. 3 |
General Regulations |
||
301.1 |
Fire |
Fire |
|
301.2 |
Building |
Building |
|
301.3-301.5 |
Fire |
Fire |
|
301.6-301.7 |
Plumbing |
Plumbing |
|
301.8-301.12 |
Building |
Building |
|
301.13 |
Building/Fire |
Building |
|
301.14-301.15 |
Building |
Building |
|
302 |
Building |
Building |
|
303 |
Plumbing |
Plumbing |
|
304-305 |
Fire |
Fire |
|
306-306.3 |
Building |
Building |
|
306.3.1 |
Electrical |
Electrical |
|
306.4 |
Building |
Building |
|
306.4.1 |
Electrical |
Electrical |
|
306.5-306.5.1 |
Building |
Building |
|
306.5.2 |
Electrical |
Electrical |
|
306.6 |
Building/Fire |
Building |
|
307 |
Plumbing |
Plumbing |
|
308 |
Fire |
Fire |
|
309 |
Electrical |
Electrical |
|
310 |
Plumbing/ Electrical |
Plumbing-except when bonded to electrical service equipment, then Electrical |
|
Ch. 4 |
Gas Piping Installation |
Plumbing |
Plumbing |
Ch. 5 |
Chimneys and Vents |
Building/Fire |
Fire (except 501.3, 501.11, 501.15.3, 503.5.3, 503.5.8-503.5.10 503.5.11) |
501.3 |
Building/Fire |
Building |
|
501.11 |
Building/Fire |
Building |
|
501.15.3 |
Building/Fire |
Building |
|
503.5.3 |
Building/Fire |
Building |
|
503.5.8-503.5.10 |
Building |
Building |
|
503.5.11 |
Building/Fire |
Fire |
|
Ch. 6 |
Specific Appliances |
||
602-603 |
Plumbing/Fire |
Plumbing |
|
604 |
Building/Fire |
Building |
|
605 |
Fire/Plumbing |
Fire |
|
606-607 |
Building/Fire |
Fire |
|
608-615 |
Building/Fire |
Building |
|
616 |
Fire |
Fire |
|
617 |
Electrical/ Plumbing |
Electrical if electric/Plumbing if oil fired |
|
618 |
Building/Fire |
Building |
|
619 |
Plumbing |
Plumbing |
|
620-622 |
Building/Fire |
Building |
|
623 |
Fire |
Fire |
|
624 |
Plumbing |
Plumbing |
|
625 |
Building/Fire |
Building |
|
626 |
Plumbing |
Plumbing |
|
627.1-627.3 |
Plumbing |
Plumbing |
|
627.4-627.7 |
Building/Fire |
Building |
|
627.8-627.9 |
Plumbing |
Plumbing |
|
627.10 |
Electrical |
Electrical |
|
628.1-628.3 |
Building/Fire |
Building |
|
628.4 |
Plumbing |
Plumbing |
|
629-630 |
Building/Fire |
Building |
|
631-632 |
Plumbing |
Plumbing |
|
633 |
Fire |
Fire |
|
634 |
See Chapter 7 |
See Chapter 7 |
|
635 |
Fire/Plumbing |
Plumbing |
|
Ch. 7 |
Gaseous Hydrogen Systems |
||
703.1 |
Building |
Building |
|
703.2 |
Building/Fire |
Fire |
|
703.3-703.5 |
Fire |
Fire |
|
703.6 |
Electrical |
Electrical |
|
704.1 |
Fire |
Fire |
|
704.1.1 |
Fire |
Fire |
|
704.1.2 |
Plumbing |
Plumbing |
|
704.2-704.4 |
Fire |
Fire |
|
705 |
Plumbing |
Plumbing |
|
706.1 |
Building |
Building |
|
706.2 |
Building/Fire |
Fire |
|
706.3 |
Fire |
Fire |
|
707-708 |
Fire |
Fire |
(b) Where responsibility for enforcement of a section is joint between two officials and there are conflicting opinions regarding enforcement, the construction official shall rule as to which interpretation or application shall be followed.
(c) Responsibility for enforcement of the Radon Hazard Subcode shall be in accordance with N.J.A.C. 5:23-10.3.
(d) Any mechanical inspector employed by the Department or by a municipality, and so assigned by the construction official, shall have the responsibility for enforcement of the provisions of the code, except work involving the installation or replacement of backflow preventers or electrical work, for the installation and replacement of heating or cooling equipment or water heaters or other mechanical equipment, such as refrigeration, air conditioning, or ventilating apparatus, gas piping or heating systems, or stand-by power generators, in existing buildings of Group R-3 or R-5. For a new installation, the mechanical inspector shall have this enforcement responsibility provided that the installation does not penetrate a fire-rated assembly.