Section 12:190-7.13 - Initiation with safety fuse and cap

Universal Citation: NJ Admin Code 12:190-7.13

Current through Register Vol. 56, No. 6, March 18, 2024

(a) The safety fuse shall be in good condition. It shall not be kinked, bent sharply or handled roughly.

(b) Each spool of safety fuse shall be test burned to determine the burning rate. The burning rate shall be posted to assure that all persons using the fuse will know the burning rate.

(c) Blasting caps shall be crimped to the fuse only with a tool designed for that specific purpose. This work shall be performed at a safe location.

(d) Fuses shall be at least 48 inches long.

(e) Fuses shall be ignited with hot-wire lighter, lead spitters, ignitor cord, or other such devices designed for this purpose.

(f) Timing shall be such that the fuse in the last blast hole to fire is burning within the hole before the first blast hole fires.

(g) When cap and fuse are to be lighted, two individuals shall be present. No individual shall light more than 15 individual fires.

Disclaimer: These regulations may not be the most recent version. New Jersey may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.