(a) The Occupational Noise Exposure Standard, Section 1910.95 of 29 CFR Part 1910, adopted by reference at 12:100-4.2(a)6, shall be applicable at indoor firing ranges.

(b) To minimize the effect of peak sound pressure levels on individuals in the indoor range, all reflecting walls should be covered with high efficiency sound absorbing material. The coverings should be designed to permit easy cleaning and access to the acoustical material for periodic replacement.

(c) The floors directly behind the shooting booths should be covered with acoustical flooring.

(d) Firing range control rooms should be acoustically treated to reduce noise levels.

(e) The bullet trap should not be anchored or attached to any structural support for the building.

Disclaimer: These regulations may not be the most recent version. New Jersey may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.