Current through Register No. 40, October 3, 2024
(a) In display locations where ground excavation or trenching is not feasible, due to unremovable ground conditions such as tar, the commissioner or the fire chief shall allow single fire and reloadable mortars of up to 6 inches in diameter to be buried to 3/4 its length in sturdy wooden boxes with partitions, at least 2 feet wide by 3 feet in height filled with clean sand, and provided with 18 inch spacing between mortars or direct that the display location be moved to a site where trenching is feasible.
(b) In lieu of using sturdy wooden boxes with partitions, as set forth in (a) above, sturdy 55 gallon steel drums filled with rock-free sand or earth may be used so long as no more than 2 mortars are placed in each drum.
(c) The commissioner or fire chief, in determining whether the display location shall be moved to a site where trenching is feasible, shall consider:
(See Revision Note at Chapter heading for Saf-C 5000) #6055, eff 7-1-95, EXPIRED: 7-1-03
New. #8117, INTERIM, eff 7-14-04, EXPIRED: 1-10-05
New. #8261, eff 1-21-05; ss by #9765-A, eff 8-2-10