New Hampshire Code of Administrative Rules
Saf - Department of Safety
Subtitle Saf-C - Commissioner, Department of Safety
Chapter Saf-C 400 - WATERCRAFT SAFETY RULES
Part Saf-C 403 - EQUIPMENT REQUIREMENTS
Section Saf-C 403.05 - Fire Extinguishers
Current through Register No. 40, October 3, 2024
(a) Every motorboat shall be provided with such number, size, and type of fire extinguishers approved by Underwriter's Laboratories, as set forth below, which are capable of promptly and completely extinguishing burning fuel. Said extinguishers shall be kept in condition for immediate use and so placed as to be readily accessible at all times.
(b) The provisions of this section shall not apply to:
(c) A minimum number of B-1 hand portable fire extinguishers shall be required as set forth in Table 400.1 below:
Table 400-1 B-1 Hand Portable Fire Extinguishers
Class of Motorboat Fire | No Fixed Extinguishing System in Machinery Spaces | Fixed Fire Extinguishing System in Machinery Spaces |
A | 1 | 0 |
I | 1 | 0 |
II | 2 | 1 |
III | 3 | 2 |
(c) One B-2 hand portable fire extinguisher may be substituted for 2 B-1 hand portable fire extinguishers.
(d) Fire extinguisher classification shall comply with the requirements as set forth in Table 400.2 below:
Table 400.2
Classification Type Size | Foam (Gallons) | Carbon Dioxide (Pounds) | Dry Chemicals (Pounds) |
B-1 | 1 1/4 | 4 | 2 |
B-2 | 1 1/2 | 15 | 10 |
#2351, eff 4-25-83; ss by #3010, eff 5-2-85; ss by #4562, eff 1-3-89; ss by #5862, eff 7-1-94; amd by #6005, eff 3-24-95; paragraphs (a), (c) and (d) EXPIRED: 7-1-00; paragraph (b) EXPIRED 3-24-03
New. #7904, INTERIM, eff 6-24-03, EXPIRED: 12-21-03
New. #8093, EMERGENCY, eff 5-28-04, EXPIRES: 11-24-04; ss by #8172, eff 9-21-04; ss by #10293, eff 3-20-13