New Hampshire Code of Administrative Rules
Saf - Department of Safety
Subtitle Saf-C - Commissioner, Department of Safety
Chapter Saf-C 3300 - RULES FOR MODULAR BUILDINGS AND BUILDING COMPONENTS
Part Saf-C 3306 - MANUFACTURER BUILDING SYSTEMS FOR AGENCY REVIEW AND APPROVAL
Section Saf-C 3306.03 - Construction Details

Universal Citation: NH Admin Rules Saf-C 3306.03

Current through Register No. 40, October 3, 2024

Documents for modular buildings and building components shall include the following:

(a) Typical details, including:

(1) Methods of installation of modular buildings or building components on foundations or to each other;

(2) Floor plan(s) and elevation(s);

(3) Cross sections specific to the building system necessary to identify major building components;

(4) Details of flashing including material or gauge at openings and penetrations through roofs and subcomponent connections, including weather barriers and roof system underlayment;

(5) Attic access and attic ventilation, if required by code;

(6) Exterior wall, roof, and soffit material;

(7) Interior wall and ceiling material;

(8) Barrier free provisions, if applicable;

(9) Sizes, locations, and types of doors and windows;

(10) Foundation dimensional plans; and

(11) Insulation values and materials;

(b) Fire safety details, including:

(1) Details and locations of fire rated assemblies, including reference listing or test report for all:
a. Stairway enclosures;

b. Doors;

c. Walls;

d. Floors;

e. Ceilings;

f. Partitions;

g. Columns;

h. Roof; and

i. Other enclosures;

(2) Details of means of egress, including:
a. Aisles;

b. Exits;

c. Corridors;

d. Passageways;

e. Stairway enclosures; and

f. Handrails and guardrails;

(3) Flame spread and smoke development classification of interior finish materials;

(4) Location of required draftstops, fireblocking, and through-penetration fire-rated assemblies;

(5) Opening protectives in fire resistance rated systems and assemblies; and

(6) Drawings and calculations of fire suppression systems, standpipes, fire alarms, and detection systems, if required;

(c) Structural details, including:

(1) Calculations of structural members and test results, except when compliance can be demonstrated through code tables, product manufacturer handbooks, and listing document;

(2) Details of structural elements, including framing, spacing, size, and connections;

(3) Grade, type, and specifications of materials;

(4) Schedule of roof, floor, wind, and seismic loads on which design is based;

(5) Column loads and column schedule; and

(6) Design and calculations of high-wind connections, including required foundation load, as applicable;

(d) Mechanical details, including:

(1) Location of all equipment, appliances, and baseboard radiation units;

(2) Equipment and appliance listing and labeling agencies;

(3) Energy conservation calculations, using rescheck, as defined in Saf-C 3302.24;

(4) Make, model number, and input/output rating of all equipment and appliances;

(5) Duct and register locations, sizes, and materials;

(6) Method of providing combustion air, if required; and

(7) Location of flues, vents, and chimneys, clearances from air intakes, combustible materials, and other vents and flues;

(e) Plumbing details, including:

(1) Schematic drawing of the:
a. Plumbing layout, including the size of piping, fittings, traps, and vents;

b. Cleanouts and valves; and

c. Gas, water, and drainage systems; and

(2) Plumbing materials, including:
a. Location of all equipment, appliances, and safety controls to be used;

b. Make, model, rating, and capacity of equipment and appliances; and

c. Equipment and appliance listing or labeling agencies; and

(f) Electrical details, including:

(1) Service equipment;

(2) Method of grounding service equipment;

(3) Load calculations for service and feeders;

(4) Sizes of branch circuit conductors;

(5) Size, rating and location of main disconnect and over current protective devices; and

(6) Location of outlets, junction boxes, fixtures and appliances.

#5439, eff 7-24-92; ss by #6810, INTERIM, eff 7-25-98, EXPIRES: 11-22-98; ss by #6885, eff 11-18-98;ss by #8741, INTERIM, eff 11-18-06, EXPIRED: 5-17-07

New. #9752, eff 7-9-10 (from Saf-C 3307.03)

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.