Section Saf-C 1635.08 - Electrical Requirements
Current through Register No. 40, October 3, 2024
(a) All electrical equipment including wiring, switches, controls, motors, and lights shall conform to the requirements of the National Electrical Code, NFPA 70, 2002 edition, available as noted in Appendix I.
(b) All electric motors and generators shall be provided with overload protection devices. Electrical generators, motors, proportioning devices, and all other electrical enclosures shall be electrically bonded. The grounding conductor to all such electrical equipment shall be effectively bonded to the service-entrance ground connection and to all equipment ground connections in a manner so as to provide a continuous path to ground.