New Hampshire Code of Administrative Rules
Saf - Department of Safety
Subtitle Saf-C - Commissioner, Department of Safety
Chapter Saf-C 1600 - EXPLOSIVES
Part Saf-C 1613 - CONSTRUCTION OF TYPE 4 STORAGE FACILITIES
Section Saf-C 1613.04 - Indoor Storage Facilities
Current through Register No. 40, October 3, 2024
(a) No indoor facility for the storage of low explosives shall be located in a residence or dwelling. When located in a warehouse, wholesale, or retail establishment, such storage facilities shall be provided with substantial wheels or casters to facilitate removal therefrom.
(b) No more than one indoor storage facility shall be kept in any one building. It shall be located on the floor nearest the ground level and within 10 feet of an outside exit.
(c) No indoor storage facility shall contain a quantity of low explosives in excess of 50 pounds.
(d) When unattended the building housing the storage facility shall be kept locked.
#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03
New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04