New Hampshire Code of Administrative Rules
Saf - Department of Safety
Subtitle Saf-C - Commissioner, Department of Safety
Chapter Saf-C 1600 - EXPLOSIVES
Part Saf-C 1613 - CONSTRUCTION OF TYPE 4 STORAGE FACILITIES
Section Saf-C 1613.01 - Structure
Current through Register No. 40, October 3, 2024
(a) A Type 4 storage facility may be a building, an igloo, a tunnel, a dugout, a box, a trailer, or a semi-trailer or other mobile facility and shall be fire-resistant, weather-resistant, and theft-resistant.
(b) A Type 4 storage facility shall be constructed of masonry, metal-covered wood, fabricated metal, or a combination of these materials. The walls and floors of such storage facilities shall be lined with a non-sparking material. No sparking metal construction shall be exposed below the top of walls in the interior of storage facilities, and all nails therein shall be blind-nailed or counter-sunk.
(c) Foundations shall be constructed of brick, concrete, cement block, stone, or wood posts. If piers or posts are used in lieu of a continuous foundation, the space under the facility shall be enclosed with metal.
#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03
New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04