New Hampshire Code of Administrative Rules
Saf - Department of Safety
Subtitle Saf-C - Commissioner, Department of Safety
Chapter Saf-C 1600 - EXPLOSIVES
Part Saf-C 1611 - CONSTRUCTION OF TYPE 2 STORAGE FACILITIES
Section Saf-C 1611.01 - Structure
Current through Register No. 40, October 3, 2024
(a) A Type 2 storage facility shall be a box, a trailer, a semi-trailer, or other mobile facility. It shall be bullet-resistant, fire-resistant, weather-resistant, theft-resistant, and well ventilated.
(b) Except as provided in Saf-C 1611.06, hinges and hasps shall be attached to the covers or doors by welding, riveting or bolting with the nuts on the inside of the door, in such a manner that the hinges and hasps cannot be removed when the covers or doors are closed and locked.
(c) The locking system shall consist of:
(d) Locks shall be 5-tumbler locks or its equivalent.
(e) All padlocks shall be protected with 1/4 inch steel caps constructed so as to prevent sawing or prying lever action on the locks or hasps.
#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03
New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04