Section Saf-C 1610.06 - Bullet-Resistant Ceilings and Roofs
Universal Citation: NH Admin Rules Saf-C 1610.06
Current through Register No. 40, October 3, 2024
(a) Where it is possible for a bullet to be fired directly through the roof and into the storage facility at such an angle that the bullet would strike a point below the top of inner walls, storage facilities shall be protected by one of the following methods:
(1) A sand tray shall be
located at the tops of inner walls covering the entire ceiling area, except
that portion necessary for ventilation, lined with a layer of building paper,
and filled with not less than 4 inches of coarse, dry sand; or
(2) A fabricated metal roof shall be
constructed of 3/16 inch plate steel lined with 4 inches of hardwood and for
each additional 1/16 inch of plate steel, the hardwood lining may be decreased
by one inch.
#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03
New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04
Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.