New Hampshire Code of Administrative Rules
Puc - Public Utilities Commission
Chapter Puc 500 - RULES FOR GAS SERVICE
Part Puc 505 - METER ACCURACY AND TESTING
Section Puc 505.07 - Testing Facilities and Equipment

Universal Citation: NH Admin Rules Puc 505.07

Current through Register No. 12, March 21, 2024

(a) Each utility shall maintain the equipment and facilities necessary for accurately testing all types and sizes of meters employed for the measurement of gas to its customers, unless arrangements approved by the commission, pursuant to Puc 201.05, have been made to have such testing done elsewhere.

(b) Meter provers used by the utility or its agent for the testing of meters shall be of a type recommended by the manufacturer and of a capacity of not less than 5 cubic feet.

(c) Each meter prover shall be supplied with accessories needed for accurate meter testing and shall be located in a room suitable for the work to be done.

(d) The utility shall maintain, or cause to have maintained on its behalf, the meter prover in good condition and correct adjustment so that it can determine the accuracy of any gas meter to within 1/2 of one percent.

#8259, eff 1-19-05 (from Puc 505.06 ); ss by #10334, eff 5-10-13

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.