New Hampshire Code of Administrative Rules
Lab - Commissioner, Department of Labor
Chapter Lab 1400 - SAFETY AND HEALTH OF EMPLOYEES
Part Lab 1403 - RULES FOR EMPLOYEE SAFETY AND HEALTH
Section Lab 1403.36 - Machine Guarding

Universal Citation: NH Admin Rules Lab 1403.36

Current through Register No. 12, March 21, 2024

The employer shall ensure compliance with the following requirements:

(a) Machine guarding shall be provided to protect employees from hazards such as those created by point of operation, nip points, rotating parts, flying chips and sparks.

(b) Machine guarding shall comply with the following requirements:

(1) The guard shall be such that it cannot pose an accident hazard in itself; and

(2) Point of operation guarding devices shall be so designed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

(c) Machines which require point of operation guarding shall include:

(1) Guillotine cutters;

(2) Shears;

(3) Alligator shears;

(4) Power presses;

(5) Milling machines;

(6) Power saws;

(7) Jointers; and

(8) Forming rolls and calendars.

(d) Special supplemental hand tools shall be used for placing and removing materials within the danger zone of the machine.

(e) Except as allowed by (i) below, Guards shall be required within 7 feet of the floor or working platform to protect from the following machinery:

(1) Fan blades;

(2) Belts;

(3) Pulleys;

(4) Sprockets;

(5) Chains;

(6) Flywheels;

(7) Shafting;

(8) Shaft projections;

(9) Gears;

(10) Couplings; and

(11) Rotating or reciprocating parts.

(f) Flywheels protruding through a working floor shall be guarded.

(g) Where both runs of horizontal belts are 7 feet or less from the floor or working surface, the guard shall extend at least 15 inches above the belt.

(h) Safety sleeves shall be required to guard couplings with bolts, nuts, or set screws extending beyond the flange.

(i) Belts, pulleys, and shafting located in rooms used exclusively for power transmission apparatus shall not be required to be guarded when the following requirements have been met:

(1) The basement, tower, or room occupied by transmission equipment is locked against unauthorized entrance; or

(2) The route followed by the oiler is protected in such a manner as to prevent accidents.

#4118 eff 8-22-86, EXPIRED: 8-22-92

New. #6684, eff 2-4-98, EXPIRED: 2-4-06

New. #8606, INTERIM, eff 4-12-06, EXPIRED: 10-09-06 (formerly Lab 1403.49 )

New. #8796, eff 1-11-07

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.