New Hampshire Code of Administrative Rules
Lab - Commissioner, Department of Labor
Chapter Lab 1400 - SAFETY AND HEALTH OF EMPLOYEES
Part Lab 1403 - RULES FOR EMPLOYEE SAFETY AND HEALTH
Section Lab 1403.32 - Ladders

Universal Citation: NH Admin Rules Lab 1403.32

Current through Register No. 40, October 3, 2024

The employer shall ensure compliance with the following requirements:

(a) Fixed ladders shall comply with the following requirements:

(1) Rungs shall have a minimum diameter of 3/4 inch, if metal, or 1-1/8 inches, if wood;

(2) Rungs shall be a minimum of 16 inches in length and be spaced uniformly no more than 12 inches apart;

(3) Cages, wells, or safety devices, such as fall prevention systems for ladders shall be provided on all ladders more than 20 feet in length;

(4) Landing platforms shall be provided each 30 feet of travel, where cages are provided. Where no cage is provided, landing platforms shall be provided for every 20 feet of travel;

(5) Tops of cages on fixed ladders shall extend at least 42 inches above top of landing. The bottom of the cage shall be not less than 7 feet or more than 8 feet above the base of the ladder; and

(6) Side rails shall extend 3-1/2 feet above the landing.

(b) Portable ladders shall comply with the following requirements:

(1) Stepladders shall be equipped with a metal spreader or locking device of sufficient size and strength to securely hold the front and back sections in the open position;

(2) Ladders shall be inspected prior to use and those which have developed defects shall:
a.Be withdrawn from service for repair or destruction; and

b.Be tagged or marked as "Dangerous, Do Not Use";

(3) Ladders that are not self-supporting shall be erected on a sound base at a 4/1 pitch and placed to prevent slipping;

(4) The side rails of a ladder used to gain access to a roof or platform shall extend at least 3 feet above the landing;

(5) Portable metal ladders shall not be used for electrical work or where they might contact electrical conductors; and

(6) Portable ladders shall be safely secured when not in use.

#4118 eff 8-22-86, EXPIRED: 8-22-92

New. #6684, eff 2-4-98, EXPIRED: 2-4-06

New. #8606, INTERIM, eff 4-12-06, EXPIRED: 10-09-06 (formerly Lab 1403.45)

New. #8796, eff 1-11-07

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.