New Hampshire Code of Administrative Rules
Lab - Commissioner, Department of Labor
Chapter Lab 1400 - SAFETY AND HEALTH OF EMPLOYEES
Part Lab 1403 - RULES FOR EMPLOYEE SAFETY AND HEALTH
Section Lab 1403.32 - Ladders
Universal Citation: NH Admin Rules Lab 1403.32
Current through Register No. 40, October 3, 2024
The employer shall ensure compliance with the following requirements:
(a) Fixed ladders shall comply with the following requirements:
(1)
Rungs shall have a minimum diameter of 3/4 inch, if metal, or 1-1/8 inches, if
wood;
(2) Rungs shall be a minimum
of 16 inches in length and be spaced uniformly no more than 12 inches
apart;
(3) Cages, wells, or safety
devices, such as fall prevention systems for ladders shall be provided on all
ladders more than 20 feet in length;
(4) Landing platforms shall be provided each
30 feet of travel, where cages are provided. Where no cage is provided, landing
platforms shall be provided for every 20 feet of travel;
(5) Tops of cages on fixed ladders shall
extend at least 42 inches above top of landing. The bottom of the cage shall be
not less than 7 feet or more than 8 feet above the base of the ladder;
and
(6) Side rails shall extend
3-1/2 feet above the landing.
(b) Portable ladders shall comply with the following requirements:
(1) Stepladders shall
be equipped with a metal spreader or locking device of sufficient size and
strength to securely hold the front and back sections in the open
position;
(2) Ladders shall be
inspected prior to use and those which have developed defects shall:
a.Be withdrawn from service for repair or
destruction; and
b.Be tagged or
marked as "Dangerous, Do Not Use";
(3) Ladders that are not self-supporting
shall be erected on a sound base at a 4/1 pitch and placed to prevent
slipping;
(4) The side rails of a
ladder used to gain access to a roof or platform shall extend at least 3 feet
above the landing;
(5) Portable
metal ladders shall not be used for electrical work or where they might contact
electrical conductors; and
(6)
Portable ladders shall be safely secured when not in use.
#4118 eff 8-22-86, EXPIRED: 8-22-92
New. #6684, eff 2-4-98, EXPIRED: 2-4-06
New. #8606, INTERIM, eff 4-12-06, EXPIRED: 10-09-06 (formerly Lab 1403.45)
New. #8796, eff 1-11-07
Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.