New Hampshire Code of Administrative Rules
Lab - Commissioner, Department of Labor
Chapter Lab 1400 - SAFETY AND HEALTH OF EMPLOYEES
Part Lab 1403 - RULES FOR EMPLOYEE SAFETY AND HEALTH
Section Lab 1403.28 - Hoists

Universal Citation: NH Admin Rules Lab 1403.28

Current through Register No. 40, October 3, 2024

The employer shall ensure compliance with the following requirements:

(a) The employer shall comply with the hoist manufacturer's specifications and limitations as to the proper use and installation of the equipment, whether at a portable or fixed location;

(b) Rated load capacities, recommended operating speeds, and special hazard warnings or instructions shall be visibly marked on cars and platforms;

(c) Hoistway entrances of material hoists shall be protected by full width gates or bars;

(d) Hoistway doors or cages of personnel hoists shall be not less than 6 feet 6 inches high and shall be protected with mechanical locks which cannot be operated from the landing side and shall be accessible only to persons on the car; and

(e) Overhead protective coverings shall be provided on the top of the hoist cage or platform.

#4118 eff 8-22-86, EXPIRED: 8-22-92

New. #6684, eff 2-4-98, EXPIRED: 2-4-06

New. #8606, INTERIM, eff 4-12-06, EXPIRED: 10-09-06 (formerly Lab 1403.39)

New. #8796, eff 1-11-07

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.