Under the authority of RSA 157-B:18 elevators, dumbwaiters, escalators and moving walks installed before January 1, 1968 shall conform to the American Standard Safety Code for Elevators, Escalators, and Moving Walks, A-17.1-1965 with supplements A-17.1a-1967 and A-17.1b-1968 available as specified in Appendix II with the following modifications:

(a) Delete rule 100.6 b in its entirety;

(b) Delete rule 101.2 in its entirety;

(c) Delete rule 101.3 in its entirety;

(d) Delete rule 101.4 in its entirety;

(e) Delete rule 102 in its entirety;

(f) Rewrite the first sentence of rule 107.1a to read: "When the car rests on its fully compressed buffers there shall be a vertical clearance of not less than two (2) feet between the pit floor and the underside of the car platform";

(g) Delete rule 202.1a through 202.1c in their entirety; and

(h) Delete rule 208.1 in its entirety.

#4020, eff 3-21-86; ss by #5108, eff 4-2-91, EXPIRED: 4-2-97

New. #6844, eff 9-1-98; ss by #8706, INTERIM, eff 8-19-06, EXPIRED: 2-15-07

New. #8880, eff 4-28-07

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.