New Hampshire Code of Administrative Rules
Inst - Installation Standards Board
Chapter Inst 600 - MANUFACTURED HOUSING INSTALLATION STANDARDS
Part Inst 603 - INSTALLATION STANDARDS
Section Inst 603.12 - Anchoring Instructions, Security Against Wind
Current through Register No. 13, March 27, 2025
(a) After blocking and leveling the home, the installer shall secure the house against wind. The anchoring and foundation system shall be capable of meeting the loads required by 24 CFR 3280 & 3282 in effect.
(b) Anchors shall be capable of resisting a minimum total load capacity of 4725 lbs. and a working capacity of 3150 lb. Anchors and anchoring equipment shall be certified by an engineer or tested to national standards and installed as specified by the anchor manufacturer.
(c) Tie-down straps shall conform to the following:
(d) Installers shall use diagonal tie downs in both transverse and longitudinal directions for single wide and doublewide houses.
(e) The number of anchors and spacing of anchors shall conform to manufacturer's installation instructions.
(f) Each anchor shall be manufactured and installed in accordance with NFPA 225, 2005 edition.
(g) If side-wall or over the roof straps are installed on the house, they shall be connected to an anchoring device.
#8494, eff 12-24-05; ss by #10155, eff 4-14-12