Current through Register No. 40, October 3, 2024
(a) The local components of an analytical x-ray system shall be located and arranged and include sufficient shielding or access control such that no radiation levels exist in any area surrounding the local component group which result in a dose to an individual present therein in excess of the dose limits given in He-P 4020.
(b) For systems utilizing x-ray tubes, the requirements specified in He-P 4043.05(a) shall be met at any specified tube rating.
(c) Radiation surveys, as required by He-P 4022.01, of all analytical x-ray systems sufficient to show compliance with He-P 4043.05(a) shall be performed:
(d) Radiation survey measurements shall not be required if a registrant or licensee can demonstrate compliance with He-P 4043.05(a) to the satisfaction of DHHS/RHS.
(e) Each area or room containing analytical x-ray equipment shall be conspicuously posted with a sign or signs bearing the radiation symbol and the words "CAUTION - X-RAY EQUIPMENT" in accordance with He-P 4022.11.
#6827, eff 8-6-98; ss by #8692, INTERIM, eff 7-27-06, EXPIRES: 2-2-07; ss by #8808, eff 1-24-07