New Hampshire Code of Administrative Rules
He - Department of Health and Human Services
Subtitle He-P - Former Division of Public Health Services
Chapter He-P 4000 - NEW HAMPSHIRE RULES FOR THE CONTROL OF RADIATION
Part He-P 4034 - RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS
Section He-P 4034.13 - Permanent Radiographic Installations
Current through Register No. 40, October 3, 2024
(a) Each entrance that is used for personnel access to the high radiation area in a permanent radiographic installation shall be equipped with:
(b) The alarm system described in He-P 4034.13(a) (2) shall be tested for proper operation of both the visible and audible signals, with a radiation source, each day before the installation is used for radiographic operations.
(c) Entrance control devices that reduce the radiation level upon entry as designated in He-P 4034.13(a) (1) shall be tested monthly.
(d) If an entrance control device or an alarm system is not operating properly, it shall be immediately labeled as defective and repaired within 7 calendar days.
(e) An installation with a defective entrance control device or alarm system may continue to be used for a 7-day period, provided the licensee or registrant implements the continuous surveillance requirements of He-P 4034.22 and an alarming ratemeter is used.
(f) The licensee's inspection and maintenance program shall include procedures to ensure that Type B packages used to transport radioactive materials are shipped and maintained in accordance with the certificate of registration or other approval.
(See Revision Note at part heading for He-P 4034) #6942, eff 2-1-99; ss by #8800, INTERIM, eff 2-1-07, EXPIRED: 7-31-07
New. #8959, eff 8-7-07