New Hampshire Code of Administrative Rules
He - Department of Health and Human Services
Subtitle He-P - Former Division of Public Health Services
Chapter He-P 4000 - NEW HAMPSHIRE RULES FOR THE CONTROL OF RADIATION
Part He-P 4022 - SURVEYS AND MONITORING
Section He-P 4022.03 - Location of Individual Monitoring Devices
Universal Citation: NH Admin Rules He-P 4022.03
Current through Register No. 40, October 3, 2024
(a) Each licensee or registrant shall ensure that individuals who are required to monitor occupational doses in accordance with He-P 4022.02(a) wear monitoring devices.
(b) Individual monitoring devices shall be worn as follows:
(1) An
individual monitoring device used for monitoring the dose to the whole body
shall be worn at the unshielded location of the whole body likely to receive
the highest exposure;
(2) When a
protective apron is worn, the location of the individual monitoring device
shall be at the neck;
(3) An
individual monitoring device used for monitoring the dose to an embryo/fetus of
a declared pregnant woman, pursuant to
He-P
4020.12(a) , shall be located under
the protective apron at the waist;
(4) An individual monitoring device used for
monitoring the lens dose equivalent, in accordance with
He-P
4020.05(a) (2) , a., shall be
located:
a. At the neck and outside the
protective apron if being worn by the monitored individual; or
b. At an unshielded location close to the
eye;
(5) An individual
monitoring device used for monitoring the dose to the extremities, in
accordance with He-P 4020.05(a) (2)
, b., shall be worn on the extremity likely
to receive the highest exposure;
(6) Each individual monitoring device used in
accordance with He-P 4022.03(b) (5)
shall be oriented to measure the highest
dose to the extremity being monitored;
(7) One individual monitoring device used to
determine the effective dose equivalent for external radiation pursuant to
He-P
4020.05(g) and
He-P
4022.02(b) (5) , shall be located at
the neck outside the protective apron;
(8) If two individual monitoring devices are
used to determine the effective dose equivalent for external radiation pursuant
to He-P
4020.05(g) and
He-P
4022.02(b) (5) , they shall be
located:
a. One at the neck outside the
protective apron; and
b. One under
the protective apron at the waist; and
(9) Two individual monitoring devices shall
be used and worn in accordance with
He-P
4022.03(b) (8) by declared pregnant
woman.
#5903, eff 2-1-95; ss by #6827, eff 8-6-98; ss by #8488, eff 11-18-05; ss by #8808, eff 1-24-07
Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.