New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wt - Wetlands Programs
Chapter Env-Wt 500 - PROJECT-SPECIFIC REQUIREMENTS
Part Env-Wt 512 - BREAKWATERS
Section Env-Wt 512.04 - Breakwater Design Requirements
Current through Register No. 13, March 27, 2025
In addition to meeting all applicable design requirements established in Env-Wt 300, the following design requirements shall apply to breakwaters:
(a) The height of the breakwater shall not exceed 3 feet above the normal high water line;
(b) The width of the breakwater at its highest point shall not exceed 3 feet;
(c) The side slopes of the breakwater shall be 1:1.5, rise to run, or steeper;
(d) The sides and top of the breakwater shall have irregular surfaces to diffuse wave activity;
(e) The breakwater, when measured from the normal high water line, shall have:
(f) The proposed configuration for the breakwater shall be the least impacting option available for breakwater construction for that site;
(g) No portion of the breakwater, including any portion underwater, shall be placed within 20 feet of an abutting property line or its imaginary extension into the water; and
(h) The breakwater shall be constructed of stone, concrete, wood, or other inert materials, consistent with the individual conditions of each site.