New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wq - Water Quality and Quantity Programs
Chapter Env-Wq 1000 - SUBDIVISIONS; INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
Part Env-Wq 1023 - OPERATING REQUIREMENTS
Section Env-Wq 1023.02 - Gravity Grease Interceptor Inspection and Pumping Requirements

Universal Citation: NH Admin Rules Env-Wq 1023.02

Current through Register No. 13, March 27, 2025

(a) Gravity grease interceptors shall be inspected for accumulation of sludge and surface scum or grease at a frequency sufficient to allow the tank to be pumped by a licensed septage hauler when the combined thickness is equal to 25% or more of the tank depth or the sludge is at the level of the outlet tee.

(b) Grease shall be removed from a gravity grease interceptor only by a licensed septage hauling vehicle.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.