(a) Septic tanks shall be inspected for accumulation of sludge and surface scum at a frequency sufficient to allow the tank to be pumped by a licensed septage hauler when the combined thickness of the sludge and surface scum equal 1/3 or more of the tank depth.

(b) For any septic tank having cast-in concrete baffles, the baffles shall be:

(1) Inspected for structural integrity when the tank is inspected pursuant to (a), above; and

(2) Replaced if no longer functioning as required.

(c) Septage and effluent shall be discharged from a septic tank only to:

(1) An approved or grandfathered effluent disposal area; or

(2) A licensed septage hauling vehicle.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.