(a) Sidewall surfaces in trench systems shall be used in calculating the EDA only if the septic tank outlet is at a higher elevation than the top of the EDA.

(b) The effective EDA for trenches shall be calculated as twice the effective sidewall surface added to the width, multiplied by the length and then multiplied by the number of trenches, as shown in the following equation:

{trench length x [trench width + (trench depth x 2)] } x number of trenches

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.