(a) Each bed that includes concrete chambers shall be constructed on a 6 inch level layer of:
(1) Medium to coarse textured sand, with an
effective size of 0.25 to 2.0 mm, no greater than 5% passing the number 200
sieve, and no particles larger than 3/4 inch; or
(2) Materials meeting the ASTM C-33
specification.
(b) Filter fabric or galvanized wire mesh shall be placed around the chambers prior to placing the septic stone.
(c) The pipe conveying effluent from the septic tank to the bed shall empty into either a velocity reducing pit, a splash plate, or internal distribution system.
(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08
Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.