(a) The pipe, laid in a bed or trench of sufficient width and depth, shall be supported by approved septic stone as specified in (b), below.

(b) Approved septic stone shall be clean, uniformly-sized washed crushed stone, washed rock, or similar aggregate sized as specified in Table 1014-2, below.

(c) Approved septic stone shall be certified by its producer or distributer as meeting the sieve size and percent passing by weight requirements specified in Table 1014-2, below, based on testing done in accordance with test method T11 as published by AASHTO:

Table 1016-2: Approved Septic Stone Requirements

Sieve Size

Percent Passing By Weight

2 inches

100

1.5 inches

90 - 100

3/4 inch

0 - 20

#4

0 - 5

#200

0 - 2

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.