(a) A septic tank may be replaced without department approval only if:

(1) The existing septic tank is replaced with one or more tanks of the same liquid capacity or larger;

(2) The replacement tank is installed in the location of the existing tank so that no waiver to any set-back is needed;

(3) The ISDS does not need to be repaired or replaced, as defined in Env-Wq 1002; and

(4) The replacement tank is installed by a permitted installer, except a homeowner may replace the tank for the homeowner's own domicile.

(b) Any septic tank(s) replaced or added as part of a replacement ISDS shall be shown on the plans submitted with the application.

(c) If below-grade plumbing fixtures are to be connected to an existing state-approved ISDS, amended plans shall be submitted as specified in Env-Wq 1004.08 if the liquid capacity of septic tank is required by Env-Wq 1010.01(i) to be increased and a septic tank is added or a single-compartment septic tank is replaced with a multi-compartment septic tank.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.