New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wq - Water Quality and Quantity Programs
Chapter Env-Wq 1000 - SUBDIVISIONS; INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
Part Env-Wq 1010 - SEPTIC TANKS
Section Env-Wq 1010.13 - Ledge Tanks
Universal Citation: NH Admin Rules Env-Wq 1010.13
Current through Register No. 13, March 27, 2025
(a) Subject to (b), below, a ledge tank shall be used only on a ledge lot as defined in Env-Wq 1002.
(b) A ledge tank may be used on a lot that is not a ledge lot if:
(1) The location for the
septic tank shown on the approved plan turns out to not be suitable, for
example due to the presence of boulders;
(2) There is no other suitable location for
the septic tank; and
(3) An amended
plan is available at the final inspection in accordance with Env-Wq
1004.08.
(c) To ensure adequate settling of solids when a ledge tank is used, total septic tank volume shall be twice the septic tank capacity specified in Env-Wq 1010.01 or Env-Wq 1010.02, as applicable. Such additional capacity may be achieved using 2 or more ledge tanks in series.
(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11
Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.