(a) The distance between the liquid line and the interior surface of the top of the tank shall be equal to approximately 20% of the liquid depth.

(b) The interior of the septic tank shall provide:

(1) A total liquid surface area of not less than 25 ft2; and

(2) A total length of not less than 6 feet between the inlet and the outlet of the septic tank.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.