(a) All connections between a septic tank and the pipes leading to and exiting from the septic tank shall be sealed with a watertight, flexible joint connector that:

(1) Will accommodate normal movement of the septic tank without leaking or breaking; and

(2) Has been certified by its manufacturer or distributer as meeting or exceeding the applicable standard in ASTM C 1644-06, section 7.

(b) The slope of the interior length of any pipe that extends into a septic tank shall not exceed the minimum pitch specified in Env-Wq 1009.06(a).

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.