New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wq - Water Quality and Quantity Programs
Chapter Env-Wq 1000 - SUBDIVISIONS; INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
Part Env-Wq 1010 - SEPTIC TANKS
Section Env-Wq 1010.06 - Septic Tank Design Requirements
Current through Register No. 13, March 27, 2025
(a) The outlet of a septic tank shall be at least 2 inches but not more than 4 inches below the inlet to the septic tank.
(b) Any septic tank made of concrete shall be certified by its manufacturer or distributer as meeting or exceeding the following design strength requirements:
(c) Any precast concrete septic tank shall be certified by its manufacturer or distributer as meeting the applicable requirements of ASTM C1227.
(d) Any septic tank fabricated from material other than concrete shall be certified by its manufacturer or distributer as being designed for loads that are equivalent to those specified in (b)(1)-(4), above.
(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11