(a) Bedding material beneath a septic tank shall:

(1) Consist of at least 4 inches of sand or crushed stone placed on a firm and uniform base;

(2) Be level and compacted so as to prevent differential settling of the ground underneath the tank; and

(3) Not bear on boulders or rock edges or any aggregate in excess of 3 inches in size.

(b) Backfill around a septic tank shall be:

(1) Placed in lifts as specified by the tank manufacturer, but in no case greater than 12 inches; and

(2) Compacted in a manner that does not damage the structural integrity of the tank.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.