New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wq - Water Quality and Quantity Programs
Chapter Env-Wq 1000 - SUBDIVISIONS; INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
Part Env-Wq 1009 - SEWER LINES
Section Env-Wq 1009.06 - Slope of Pipe

Universal Citation: NH Admin Rules Env-Wq 1009.06

Current through Register No. 13, March 27, 2025

(a) The slope of the pipe from the building to the septic tank shall be not less than 2% and not more than 15%.

(b) The pipe shall be below ground surface for not less than 5 feet leading to the septic tank inlet.

(c) The slope of the pipe from the septic tank to the distribution box shall be not less than 1/8 inch per foot.

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.