New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-Wq - Water Quality and Quantity Programs
Chapter Env-Wq 1000 - SUBDIVISIONS; INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
Part Env-Wq 1009 - SEWER LINES
Section Env-Wq 1009.02 - Crossing Water Lines

Universal Citation: NH Admin Rules Env-Wq 1009.02

Current through Register No. 13, March 27, 2025

(a) Subject to (b) and (c), below, where a water line must cross a sewer line, the sewer line shall be at least 18 inches below the water line.

(b) The water line may be closer than 18 inches to the sewer line if the water line or sewer line is encased in concrete or pipe having an SDR of 26 for a distance of 10 feet on both sides of the line being crossed.

(c) If placing the sewer line below the water line would require a sewage pump to be used, the sewer line may be placed above the water line provided one of the lines is sleeved as provided in (b), above.

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.