New Hampshire Code of Administrative Rules
Env - Department of Environmental Services
Subtitle Env-A - Air Related Programs (formerly designated as rules of Division of Air Resources.)
Chapter Env-A 1800 - ASBESTOS MANAGEMENT AND CONTROL
Part Env-A 1805 - WORK PRACTICE REQUIREMENTS
Section Env-A 1805.10 - Specific Requirements for Demolition

Universal Citation: NH Admin Rules Env-A 1805.10

Current through Register No. 13, March 27, 2025

(a) Prior to any demolition, including by intentional burning, of a structure or portion of a structure, all ACM shall be removed in accordance with the applicable provisions of this chapter, subject to (b) below.

(b) For clearance air sampling as described in Env-A 1805.09, an acceptable result shall be 0.10 fibers of length greater than 5 microns per cubic centimeter of air as determined by phase contrast optical microscopy, performed as described in "Asbestos and Other Fibers by PCM: Method 7400, Issue 2", NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94, available as noted in Appendix B.

(See Revision Note at chapter heading for Env-A 1800) #9298, eff 10-21-08

Disclaimer: These regulations may not be the most recent version. New Hampshire may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.