Nevada Administrative Code
Chapter 705 - Railroads
STANDARDS AND REQUIREMENTS FOR HEALTH AND SAFETY
Minimum Standards for Walkways
Section 705.177 - Alongside tracks at short-line and branch-line turnouts and certain power-operated turnouts

Universal Citation: NV Admin Code 705.177

Current through December 12, 2024

1. Walkways alongside tracks at short-line and branch-line turnouts and, except as otherwise provided in NAC 705.181, at all power-operated turnouts, in addition to the requirements of NAC 705.160, must:

(a) Be present on the switch stand side of the track from not less than 50 feet ahead of the switch stand to not less than the 12-foot-6-inch clearance point behind the switch stand;

(b) If 10 feet or more from the switch stand, be not less than 5 feet in width;

(c) If less than 10 feet, but more than 4 feet from the switch stand:
(1) Be not less than 5 feet in width;

(2) Have a straight outer edge; and

(3) Occupy a total area of not less than 39 square feet; and

(d) If 4 feet or less from the switch stand, be not less than 3 feet in width.

2. The following diagram illustrates the requirements set forth in subsection 1:

Click here to view image.

Added to NAC by Pub. Utilities Comm'n by R051-01, eff. 12-17-2001

NRS 703.1545, 704.280, 704.307

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.