Nevada Administrative Code
Chapter 705 - Railroads
STANDARDS AND REQUIREMENTS FOR HEALTH AND SAFETY
Minimum Standards for Walkways
Section 705.174 - Alongside track at main-line turnouts entering yards or serving industry tracks

Universal Citation: NV Admin Code 705.174

Current through December 12, 2024

1. Except as otherwise provided in NAC 705.177 and 705.181, walkways alongside track at main-line turnouts entering yards or serving industry tracks, in addition to the requirements of NAC 705.160, must:

(a) Be present on the switch stand side of the track from not less than 50 feet ahead of each switch stand to not less than 25 feet beyond the 12-foot-6-inch clearance point behind the switch stand;

(b) If 20 feet or more from the switch stand, be not less than 6 feet in width;

(c) If less than 20 feet, but more than 4 feet from the switch stand:
(1) Be not less than 6 feet in width;

(2) Have a straight outer edge; and

(3) Occupy a total area of not less than 120 square feet; and

(d) If 4 feet or less from the switch stand, be not less than 3 feet in width.

2. The following diagram illustrates the requirements set forth in subsection 1:

Click here to view image.

Added to NAC by Pub. Utilities Comm'n by R051-01, eff. 12-17-2001

NRS 703.1545, 704.280, 704.307

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.