Nevada Administrative Code
Chapter 645D - Inspectors of Structures
STANDARDS OF PRACTICE
Inspection of Structures
Section 645D.560 - Roofing components
Universal Citation: NV Admin Code 645D.560
Current through September 16, 2024
1. A certified inspector shall inspect the roofing components of the structure being inspected, including, but not limited to:
(a) The roof covering;
(b) The flashing;
(c) The insulation;
(d) The ventilation;
(e) The soffits and fascia; and
(f) The skylights, roof accessories and penetrations.
2. The inspection of roofing components must include, without limitation:
(a) An identification and description of the materials of the visible roof structure, roof flashing, skylights, penetrations, ventilation devices and roof drainage;
(b) An evaluation of the condition of the readily accessible attic areas;
(c) A determination of the type, condition and approximate thickness of the attic insulation; and
(d) A description of the method of observation used to inspect the roof.
Added to NAC by Real Estate Div. by R214-97, eff. 5-11-98
NRS 645D.120
Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.