Nevada Administrative Code
Chapter 618 - Occupational Safety and Health
ABATEMENT OF ASBESTOS
Performance of Activities for Abatement
Section 618.960 - Demolition of building or structure

Universal Citation: NV Admin Code 618.960

Current through February 27, 2024

1. Before a building or structure which contains friable materials containing asbestos may be demolished, the asbestos must be removed pursuant to the requirements set forth in 29 C.F.R. § 1926.1101 and NAC 618.9155.

2. Before a building or structure may be demolished, a licensed inspector must visually inspect the building or structure to determine whether the friable material containing asbestos has been removed. The inspector shall provide written proof of his or her findings to the contractor responsible for demolition and the owner of the building or structure.

3. Air monitoring for a final clearance pursuant to NAC 618.956 is not required before the demolition of a structure unless the area is to be entered by unprotected personnel before demolition or reoccupied after partial demolition.

Added to NAC by Dep't of Industrial Relations, 12-19-89, eff. 1-1-90; A by Div. of Industrial Relations by R142-98, 2-28-2000

NRS 618.295, 618.760, 618.765

Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.