Nevada Administrative Code
Chapter 535 - DAMS AND OTHER OBSTRUCTIONS
CONSTRUCTION, RECONSTRUCTION, ALTERATION AND DECOMMISSIONING OF DAMS
Section 535.250 - Requirements for approval concerning earthquakes
Current through December 12, 2024
1. Except as otherwise provided in NAC 535.220, to obtain the approval of the State Engineer pursuant to NRS NRS 535.010, the plans and specifications must, in addition to all other applicable requirements, demonstrate to the satisfaction of the State Engineer that the dam is able to accommodate an earthquake or other extreme motion event without the failure of the dam or any other unintended release of water.
2. Except as otherwise provided in subsection 3, the applicant must calculate the seismic response to a maximum credible earthquake of a dam and its foundation, including, without limitation:
Any numeric analysis of the seismic response must be calculated for the normal maximum loading condition with steady-state seepage. If a pseudo static stability analysis is performed for an earthen embankment, the calculations must be accompanied by a description of the assumptions used in deriving the seismic coefficient used in the calculations.
3. Subsection 2 does not apply to a dam classified as low hazard or to a small earth dam classified as significant hazard, if the applicant demonstrates to the satisfaction of the State Engineer that the:
Added to NAC by St. Engineer by R124-02, eff. 5-30-2003; A by R054-14, eff. 10/24/2014
NRS 532.120, 535.010