Section 445A.910 - Factors for determining logging and testing requirements for Class II wells
Universal Citation: NV Admin Code 445A.910
Current through September 16, 2024
To determine the logging and testing requirements for Class II wells, the Director will consider:
1. For surface casing intended to protect underground sources of drinking water in areas where the lithology has not been determined:
(a) Electric and caliper logs
before casing is installed; and
(b)
A cement bond, temperature or density log after the casing is set and
cemented.
2. For intermediate and long strings of casing intended to facilitate injection:
(a) Electric, porosity and gamma ray logs
before the casing is installed;
(b)
Fracture finder logs; and
(c) A
cement bond, temperature or density log after the casing is set and
cemented.
Added to NAC by Environmental Comm'n, eff. 10-21-87-Substituted in revision for NAC 445.42705
NRS 445A.425, 445A.465
Disclaimer: These regulations may not be the most recent version. Nevada may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.