Section 445A.67295 - Water hauling: Construction of equipment
Current through September 16, 2024
If the Division or the appropriate district board of health approves the use of water hauling:
1. Any containers, tanks, hoses, fittings, piping or other equipment used to store, haul or transfer the water must be constructed of materials and coatings determined to be compatible with drinking water.
2. The tanks used for hauling and equipment used for the delivery of the water must be readily accessible for cleaning.
3. A tank used for hauling must have:
4. Each opening in a tank used for hauling or a fitting used for the delivery of water must be tightly sealed by gasket, threaded joint, weld or similar means.
5. Each end of a hose or fitting used for the delivery or receipt of water must have a threaded or clamped cap. The cap must be in place when the hose or fitting is not in use and properly stored when the hose or fitting is in use.
6. A tank used for the hauling or storage of water must have an air relief vent that:
7. The discharge line from each pump or tank must have a check valve, located as near to the pump or tank as is practicable.
8. A tank used for water hauling must be filled:
If a standpipe is used, the standpipe must terminate a distance of at least two times the diameter of the pipe above the opening used for filling the tank, and the discharge end of the pipe must be capped when not in use.
9. The area used for filling a tank used for water hauling must be:
Added to NAC by Bd. of Health, eff. 2-20-97; A by Environmental Comm'n by R194-08, 10-27-2009
NRS 445A.860